14
COMPONENT TESTING PROCEDURES
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
Component
Testing
Results
Transformer, HV
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
230 to COM ..........................................
208 to COM ..........................................
230 to Ground
208 to Ground----------------------------------
Terminal 5 to 6---------------------------------
Terminal 7 to 8---------------------------------
Terminal 4 to Ground-------------------------
Less than 1
Less than 1
Infinite
Infinite
Less than 1
Less than 1
Approximately 27
Main board
See Main Board page 5
Left interlock switch assembly
Disconnect wires to switch.
(Mechanical)
With door open measure resistance from:
Monitor
– Terminals Rd- Bk..............
Primary
– Terminals Bk - Brn ...........
With door closed measure resistance from:
Monitor
– Terminals RD - BK ...........
Primary
– Terminals BK - BN ...........
After verifying or replacing the
assembly, re-connect wires to switch
and check operation of monitor circuit
before operating the oven.
Indicates continuity
Infinite
Infinite
Indicates continuity
Right interlock switch
assembly
(Mechanical)
Disconnect wires to switch.
With door open measure resistance from:
Monitor
– Terminals RD- BK ............
Secondary
– Terminals GY -RD.......
With door closed measure resistance from:
Monitor
– Terminals RD - BK ...........
Secondary
– Terminals GY - RD......
After verifying or replacing the
assembly, re-connect wires to switch
and check operation of monitor circuit
before operating the oven.
Indicates continuity
Infinite
Infinite
Indicates continuity
Transformer, control
(1) BU to (5) BR ----------------------------- --
Approximately 40
or Line Voltage
(6) YL to (10) WH-------------------------------
Approximately 1
or 28 VAC
Fan, cooling
Disconnect connector from fan.
Measure voltage at incoming leads ...........
Approximately 24VDC
Fan, exhaust
Disconnect connector from fan.
Measure voltage at incoming leads .......
Approximately 24VDC
Содержание AOC24
Страница 22: ...20 AOC24 P2004802M OC24BK P2004803M MOC24RB P2004804M ...
Страница 23: ...21 AOC24 P2004802M OC24BK P2004803M MOC24RB P2004804M ...
Страница 24: ...22 MOC24 P2004801M MOC24TR P2004842M MOC24LH P2004843M ...
Страница 25: ...23 MOC24 P2004801M MOC24TR P2004842M MOC24LH P2004843M ...
Страница 26: ...24 MOC24B P2004817M OC24BKB P2004818M OC24BKSA P2004819M ...
Страница 27: ...25 MOC24B P2004817M OC24BKB P2004818M OC24BKSA P2004819M ...