Part #: 6215-369-000
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
®
MERIDIAN 3751
Please visit
www.acorneng.com
for most current specifications.
OPTIONAL ACCESSORY INSTALLATION & ASSEMBLY
Some soaps contain corrosive additives that can cause rust in
soap dispensers. Acorn Engineering Company recommends
user/ maintenance personnel review MSDS reports of soap and
possible corrosive additives noted.
!
WARNING
Anti-Rotation
Pin
Rubber
Gasket
Washer
Black end of
Check Valve
Direction
of Flow
3/8" Nut
3/8" O.D.
Tube
Mounting
Bracket
Install soap reservoir to wall inside trap enclosure
using mounting brackets provided as shown. Wall
anchors and anchoring hardware provided by
installer.
A.
Install soap filler assembly to deck as shown.
B.
Attach 1-1/4" O.D. refill tube to soap filler
assembly and soap reservoir with provided hose
clamps.
C.
Install soap dispenser(s) onto deck by aligning
Anti-Rotation Pin with Key Hole. NOTE: Gasket
and Washer are located beneath the deck.
D.
Attach 3/8" O.D. Tubing to the dispenser(s) and
reservoir. NOTE: Check Valve must be field
spliced into tubing and installed with respect to
direction of flow.
E.
Soap Filler
Plug
Rubber Gasket
3/8" O.D.
Tubing
HINT: For best results install soap
reservoir fill hole directly below soap filler
on deck with refill tube as short and
straight as possible to facilitate refill of
soap without backup or overflow.
Date: 03/05/19