background image

ACORN ENGINEERING FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Please visit 

www.acorneng.com

for most current specifications.

Programable Piezo Pushbutton
Programming Instructions 

(Flow Time Adjustment) 

To move on to the 

5 sec timing mode

, pause and wait for the LED to flash 2 times, now you are in the 5 sec timing 

mode. Each time the button is pushed the LED will flash, adding 5 sec to the total timing cycle.

 

Each timing mode (1 sec, 5 sec or 20 sec timing mode) can be sequenced up to 100 times, that is 

 

the number of times, the button can be pushed, to increase the total timing cycle in each timing mode.

To move on to the 

20 sec timing mode

, pause and wait for the LED to flash 3 times, now you are in the 20 sec timing 

mode and each time the button is pushed the LED will flash, adding 20 sec to the total timing cycle. After programing 
is complete, pause and wait for the LED to flash 4 times and then 5 times, which completes the programming.

As soon as the cable is reconnected the LED will start flashing, it will flash 4 times, then stays on for 3 seconds. 
During the 3 second period, push the piezo button once, the LED will go out, now you are in the 

1 sec timing mode

 

and each time the button is pushed the LED will flash, adding 1 sec to the total timing cycle. 

 

When a 

timing mode is not required

 then 

do not

 push the button and wait for the next timing mode.

THE TIME SETTINGS PROGRAM USES 3 DIFFERENT TIMING MODES:

 

1 second timing mode: 

Each push of the button adds 1 second to the total timing cycle.

 

5 second timing mode:

 Each push of the button adds 5 seconds to the total timing cycle.

 

20 second timing mode:

 Each push of the button adds 20 seconds to the total timing cycle.

To program the piezo pushbutton, you will need to be able to see the back of the piezo pushbutton. 

Prevision must be made to access the back of the piezo pushbutton. There is an LED on the back of the piezo 
pushbutton under a layer of transparent epoxy, used as a programming indicator light.

In order to start the programming the piezo pushbutton, the button must be powered down. Disconnect the red power 
cable and wait 20 seconds, then reconnect the red power cable. 

NOTE: This programming procedure moves along rapidly, there is 
only about 2 or 3 seconds between programming operations.

The Button is factory set an 8 sec. timing cycle, if an 8 sec. cycle is adequate, then 

no 

programming adjustment 

is required. 

NOTE: Read the entire document before 
trying to program the piezo pushbutton.

Part #: 6215-371-000

Page 17 of 27

®

MERIDIAN  3753

Revised: 03/05/19

Содержание MERIDIAN 3753-HLH

Страница 1: ...2 NPS Supply Angle Stops An 3 8 12 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools Teflon Tape 10 10 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools ACO...

Страница 2: ...UFAS or ADA compliance is subject to the interpretation and requirements of the local code authority and is the responsibility of the installer for verification NOTE Receptacle s must be wired to a G...

Страница 3: ...se visit www acorneng com for most current specifications Page 3 of 27 ACCESSIBILITY COMPARISONS Part 6215 371 000 MERIDIAN 3753 HLH ADA ages 6 thru 12 ADA Adult 133 8 5 22 34 Rim Max ADA PROFILE 3 14...

Страница 4: ...626 855 4866 FAX 626 855 4863 INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for most current specifications Page 4 of 27 DIMENSIONAL DATA 22 90 15 30 30 4 205 8 30 30 3753 H...

Страница 5: ...ots 8 Places B Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold Supply Inlets C Waste Outlet for 1 1 2 O D P Trap Provided D 120VAC 60 Hz 3A Max GFCI Protected Electrical Receptacle E Wall Ancho...

Страница 6: ...nting Slots 8 Places B Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold Supply Inlets C Waste Outlet for 1 1 2 O D P Trap Provided E Wall Anchoring for 219 Diameter x 3 8 Long Enclosure Mounting...

Страница 7: ...Wall Anchoring for 563 Diameter x 1 Long Angle Bracket Mounting Slots 8 Places B Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold Supply Inlets C Waste Outlet for 1 1 2 O D P Trap Provided F Va...

Страница 8: ...ired Do not over tighten Place fixture on mounted angle brackets 1 and align the remaining mounted angle brackets 3 with installed wall anchors Fasten to wall loosely and proceed to step D C D E NOTE...

Страница 9: ...sembly will require field cutting and fitting by the installer Grid Strainer w 1 1 2 16 UNE Threads Flat Fiber Washer 1 1 2 16 UNI Rough Chrome Brass Jam Nut Rubber Gasket 1 1 2 16 x 1 1 4 UNI Close E...

Страница 10: ...site to ensure there are no leaks 4 To disconnect the tube from the fitting ensure that the water supply is off Push collet square towards the push in fitting body and hold While holding the collet in...

Страница 11: ...t outlet of tempering valve to spout s using 1 2 NPT connections provided 5 Turn on fixture and allow water to flow for 2 minutes Measure water temperature at outlet If water is not at desired tempera...

Страница 12: ...tivates See DETAIL C 2 Connect power supply to sensor Red light should be flashing 3 Move hand in front of sensor to distance of 2 to 4 within 5 seconds and wait until red light flashes quickly 4 Move...

Страница 13: ...el by removing 4 10 32 x 3 4 screws from front of fixture using allen head bit provided socket driver by others Replace access panel when finished SO BAT Sensor Operation Battery Powered SENSOR OPERAT...

Страница 14: ...Nut H Hand Operated 1 8 O D AIR TUBE 1 4 O D WATER LINE Leave a minimum 1 4 of polyethylene tubing through the Ferrule Nut on the pushbutton assembly This is necessary to ensure proper tubing connecti...

Страница 15: ...rs or other accessories prior to wall mounting Position bridge enclosure 5 over combined waste and accessory tubing and secure to wall All wall anchors and anchoring hardware provided by others HINT F...

Страница 16: ...i Rotation Pin Rubber Gasket Washer Black end of Check Valve Direction of Flow 3 8 Nut 3 8 O D Tube Mounting Bracket Install soap reservoir to wall inside trap enclosure using mounting brackets provid...

Страница 17: ...o out now you are in the 1 sec timing mode and each time the button is pushed the LED will flash adding 1 sec to the total timing cycle When a timing mode is not required then do not push the button a...

Страница 18: ...While the LED is steady on push button You are in the 1 sec timing mode immediately push the button 1 push equals 1 sec added to the total timing cycle LED turns off Pause and wait for the LED to flas...

Страница 19: ...INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for most current specifications BLACK RED BLACK SOLENOID CABLE RED POWER CABLE PROGRAMMING INDICATOR LED LIGHT TRANSPARENT EPO...

Страница 20: ...nsor Stops or water main closed Bad sensor to solenoid connection Debris or scale in solenoid assembly Remove solenoid pull out plunger and spring and clean with scale remover solution or pressurized...

Страница 21: ...tor seat Servomotor plate or diaphragm is obstructed Servomotor timer assembly is damaged Replace servomotor timer assembly Probable Cause Solution Valve riser tubing is crimped Straighten valve riser...

Страница 22: ...act the factory for details Refer to drawing 9927 160 002 ROUTINE CLEANING Corterra should be kept clean at all times If maintained Corterra surfaces will retain their new clean appearance indefinitel...

Страница 23: ...7 Part 6215 371 000 MERIDIAN 3753 HLH Stainless Steel Hex Head Cap Screw 20 x 3 4 Long 0206 008 000 0332 004 000 20 x 1 Thick Fender Washer COMPONENTS REPAIR PARTS Description Part No Diagram MOUNTING...

Страница 24: ...HLH Enclosure HLL Right Side Low Side 6215 126 199 6215 116 199 HLR Right Side High Side Enclosure COMPONENTS REPAIR PARTS Description Part No Diagram ENCLOSURES Bridge or Transition 6215 108 199 621...

Страница 25: ...5 371 000 MERIDIAN 3753 HLH COMPONENTS REPAIR PARTS Description Part No SPOUTS Diagram Push Button Assembly Stern Easy Remote Actuated Spout 2993 410 000 2566 270 001 Blank Piezo Pushbutton 0709 067 0...

Страница 26: ...ARTS Description Part No VALVE Diagram Optional 3 Station Hand Operated Single Temp Metering Valve Assembly Optional 3 Station 9VDC Solenoid Single Temp Valve Assembly Optional T P 3 Station Hand Oper...

Страница 27: ...hin reasonable period after receipt of the product Where claims for defects are made the defective part or parts shall be delivered to the company prepaid at City of Industry California for inspection...

Отзывы: