ROUGH-IN

 

1. Read the installation instructions prior to beginning the installation.

2. Separate parts from packaging and verify all necessary parts are accounted for and undamaged. Obtain missing or 

damaged parts from Acorn Safety prior to beginning installation.

3. Flush water supply lines prior to installation. This will remove unwanted debris from the lines and prevent unwanted 

blockages in the safety equipment.

4. In order to comply with ANSI Z358.1, the safety equipment must be inspected periodically. An inspection tag is 

provided for documentation purposes.

5. all employees at risk of contamination should be informed and trained in the use of this and any other safety 

equipment. The signage provided should be posted appropriately in close proximity to this equipment.

Installation & Operation Manual

PRELIMINARY STEPS

31

1
2

"

[800]

8"

[203]

11

1
2

"

[292]

1-1/4" NPT

WASTE

BURY DEPTH

SEE NOTE 2

3/4" NPT

FEMALE SUPPLY

BLEED HOLE

OUTLET

FREEZE RESISTANT

VALVE

GENERAL NOTES:

ALL DIMENSIONS ARE IN INCHES [MM].

STANDARD DEPTHS ARE 24, 36 AND
48 INCHES. OTHERS AVAILABLE 
UPON REQUEST.

1.

2.

NOT LESS THAN 3 CUBIC FT.
OR POROUS FILL AROUND AND
BELOW BLEED OUTLET FOR
DRAINAGE. DO NOT USE SAND.

Ø7

1

2

"

[191]

Ø

3

8

"

[10]

Ø9

1

8

"

[232]

S0310-FPB24 SHOWN FOR

REFERENCE

FLANGE MOUNTING

DETAIL

Date: 10/28/2013

Page 2 of 7

Содержание S0310-FPB

Страница 1: ...discharged solely by replacement of repair of defective material provided Acorn is notified in writing within one year from date of shipment F O B Industry California This warranty does not cover inst...

Страница 2: ...y An inspection tag is provided for documentation purposes 5 all employees at risk of contamination should be informed and trained in the use of this and any other safety equipment The signage provide...

Страница 3: ...ure to position equipment so that there is a minimum of 12 from any wall or equipment around assembled unit 2 Determine frost line and dig pit deep enough to accommodate a minimum of 3 cubic feet of p...

Страница 4: ...potable water supply 2 Inspect system for leaks 3 Operate push handles on hydrant to verify that eyewash flows properly 4 Shut off push handle and verify that the eyewash shuts off properly Step Six...

Страница 5: ...contact lenses should remove them immediately prior to or during the flush to prevent the contamination from remaining against the cornea possibly causing unnecessary damage or pain 3 Using thumb and...

Страница 6: ...G GALV PIPE 3 7101 081 000 5 8 OD x 3 8 NPTE ADAPTER 4 7101 016 000 NPT COUPLING 5 7101 054 199 CASTING DRAIN 6 7101 046 00 GASKET SS BOWL EYE FACE WASH 7 7101 008 000 BOWL EYE FACE WASH 8 7100 108 19...

Страница 7: ...E ADAPTER 4 7101 016 000 NPT COUPLING 5 7101 054 199 CASTING DRAIN 6 7101 046 00 GASKET SS BOWL EYE FACE WASH 7 7101 008 000 BOWL EYE FACE WASH 8 7100 108 199 STRAINER EYE FACE WASH 9 7100 401 000 INS...

Отзывы: