HEAT PUMP 

AIR / WATER 

 

 

WITH REGULATION 

ACOND® THERM 

OPERATING MANUAL 

Software version 140.1 and 140.2 

 

In short: 

To turn the heat pump on / off: 

 

 

If the symbol  

is on the display and the room temperature is not 

displayed, the heat pump is switched off.

 

 

Press and hold the rotary button on the room unit for about 7s. The heat pump is 
switched on, the display shows the room temperature. 

 

When the heat pump is switched on, pressing and holding the rotary button (7s) 
switches the heat pump off. 

 

To set the room temperature:

 

 

 

 

Press the rotary button.  

 

The desired indoor temperature flashes on the display.  

 

Turn the button to the right to increase the desired room temperature by 0.5 °C, turn 
the button to the left to decrease it.  

 

Press the rotary button again and the display will display the room temperature 
again. 

 

For more information, see chapter 3.1.5 on page 15. 

 

To determine the outdoor temperature: 

 

Turn the button 

to the right

 and the outdoor temperature will be displayed for 5s. 

 

To determine the temperature of service water (TUV): 

 

Turn the button 

to the left

 and the water temperature (if fitted) will be displayed for 

5s.

 

 

Содержание PRO-N

Страница 1: ...witches the heat pump off To set the room temperature Press the rotary button The desired indoor temperature flashes on the display Turn the button to the right to increase the desired room temperatur...

Страница 2: ...mperature 15 3 1 6 How to Determine Outdoor Temperature 15 3 1 7 How to Detect and Change service water Temperature 15 3 1 8 How to set the end of heating temperature 15 3 1 9 Display Fault Confirmati...

Страница 3: ...Heat pumps AIR WATER Operation manual 3 7 TECHNICAL INFORMATION IN ACCORDANCE WITH COMMISSION REGULATION EU NO 813 2013 42 8 LINKS 45...

Страница 4: ...ing installation operation and maintenance then the obligations of ACOND a s stemming from the terms of the warranty shall cease to apply ACOND a s hereby reserves the right to make changes to any par...

Страница 5: ...locally applicable occupational safety and other safety regulations This applies in particular to the use of personal protective clothing 2 1 1 Personal protective equipment Every person performing m...

Страница 6: ...can be used for degreasing Due to the risk of damage to the heat pump casing do not use any spray types in its vicinity This applies in particular for Solvents Chlorine cleaning products Paints Adhesi...

Страница 7: ...mate range of 5 C below the surrounding temperature and therefore the surrounding area may be icy and slippery Therefore install the heat pump in a manner that does not allow the out flowing air to in...

Страница 8: ...2 3 1 Water quality and volume All water including domestic hot water must meet the parameters for drinking water according to SN 252 2004 Coll however in addition the maximum total hardness must be l...

Страница 9: ...ed without a fully functioning safety valve The maximum possible operating pressure of the vessel is 0 6 MPa Occasional leakage of water from the safety valve during hot water heating is a normal phen...

Страница 10: ...mensions HxWxD mm 730x1127x498 1070X1426x557 Pump weight kg 115 195 Coolant R290 R290 Coolant weight kg 1 35 2 75 Maximum allowable pressure high pressure side bar 26 26 Maximum allowable pressure low...

Страница 11: ...23 COP A 7 W34 1 3 14 3 24 Heating capacity A12 W34 8 kW 1 76 3 88 COP A12 W34 8 1 5 36 5 92 Heating capacity A7 W36 kW 1 60 3 52 COP A7 W36 1 4 41 4 97 Heating capacity A2 W42 kW 2 48 5 53 COP A2 W4...

Страница 12: ...lower anitfreeze at least 10 C The control maintains the set temperature in the room with a tolerance of 0 5 C The regulation will stabilize after a significant intervention within 24 hours for underf...

Страница 13: ...defrosting the air heat exchanger is activated when the ACOND heat pump is running The defrost sequence starts when the evaporator temperature of the outdoor unit falls below the set value The four wa...

Страница 14: ...ipped with service water heating and the service water temperature drops below the set value an accumulation vessel enabling service water preheating and the variant of preheating in summer is selecte...

Страница 15: ...her heating costs 3 1 2 Meaning of individual symbols of the RCM2 1 control unit panel RCM2 1 Symbol Description Automatic mode Heat pump mode Bivalent heater mode 4 Cooling mode if installed If the r...

Страница 16: ...us Circulation pump Outdoor unit shutdown domestic hot water Bivalent heater on Entering parameters service water temperature regulation type operation mode Manual regime Circulating pump plate heat e...

Страница 17: ...ic view turn the button to the right A value is displayed for 5 seconds indicating the outside temperature and the thermometer symbol flashing After 5 seconds the display returns to the basic display...

Страница 18: ...rs alarms of the system Instead of room temperature the two digit number indicating the fault index flashes The fault must be confirmed by a short press of the rotary button Notes For more information...

Страница 19: ...nection of the heat pump to the Internet will be made by a service technician during the installation of the heat pump or later via the Acond service telephone line 420 601 373 073 Users access a web...

Страница 20: ...n the lower right corner and the login table page appears see Figure 2 Type your login name in the Username field Type your password in the Password field Figure 1 Website of Acond a s with login to t...

Страница 21: ...see Figure 3 to you have access the list opens by clicking the arrow in the right edge of the strip with the heat pump name Select the appropriate heat pump and click Select or press Enter The heat p...

Страница 22: ...e name and password and displaying the login page on the TecoRoute server see Figure 2 TecoRoute Login Page it is possible to check the box Create a permanent login link to facilitate the next login T...

Страница 23: ...heat pump parameters 1 The main page Figure 6 is displayed after logging into the system and at any time after clicking on the 1st menu line 2 Schedules Figure 11 allow you to set the value of the aut...

Страница 24: ...tatus pictogra m status description Inactive Active Heat pump compressor Inactive Active Heat pump fan Inactive Active Circulating pump of heating pump Inactive Active Heat pump defrosting Winter and...

Страница 25: ...e active The sun symbol indicates the summer when the heat pump only heats hot water hydrobox or maintains 45 C in the accumulation tank for service water preheating the option is located in the middl...

Страница 26: ...rmed by pressing the ENTER key or by clicking the arrow in the right part of the white input field Acond Therm control normally maintains the set temperature in the room with a tolerance of 0 5 C This...

Страница 27: ...other superior regulation If this is not respected we recommend using the Equitherm or Standard control 3 2 6 2 Equipment EQUIV BUTTON The temperature of the water in the heating system is determined...

Страница 28: ...ter temperature in the plate exchanger for the possibility of entering the desired water temperature for cooling 3 2 7 5 Off OFF button The whole system shuts down including circulators Sometimes due...

Страница 29: ...temperature accumulation container is set to 45 C Heating of the pool occurs only when the living rooms are flooded 3 2 10 Fault display In the event of a malfunction a red bar appears on the dark blu...

Страница 30: ...water For each day it is possible to enter 2 time periods in which the room temperature domestic hot water temperature at ST will be controlled to the value entered in this table At the top of the tab...

Страница 31: ...e 12 to enter 2 time periods in which service water heating will be enabled At the top of the table there is a choice whether the heat pump should follow the displayed schedule If the check box remain...

Страница 32: ...holiday even if the heating schedule is not allowed Attention if the heating times are set so that the heating does not occur at all or only for a short period of time on time off time and the service...

Страница 33: ...rol the HDO signal Bulk Remote Control switching the inexpensive electricity tariff If you check the box HDO turns off service water heating service water will not be heated at the time of the more ex...

Страница 34: ...ate the temperature of the domestic hot water corresponding to these faults points The large red number in the right part of the graph corresponds to the temperature of the domestic hot water calculat...

Страница 35: ...COND GENIUS heat pump information about the current system used earth or air is displayed in the top row next to the information about the installation location and pump type 4 Alarms faults and troub...

Страница 36: ...aulty cable probe resistance exceeds limit values Call Service P08 SOLAR SENSOR FAULT Probe missing faulty faulty cable probe resistance exceeds limit values Call Service P09 IT S AN INTERNAL MALFUNCT...

Страница 37: ...COMPRESSOR RUNNING PHASE SEQUENCE Compressor not running electrical fault balancing problems of the power grid undervoltage at some stage Check that the compressor is rotating If not call service A04...

Страница 38: ...self resolve W02 LOW TEMPERATURE IN ACCU On arrival when using another heat source e g boiler at higher outdoor temperature Warning only starts the heat pump disappears on its own W03 LOW TEMPERATURE...

Страница 39: ...2 Problem with compressor driver Call Service 5 Regular checks 5 1 Inspection of intake and exhaust grilles and openings Check the front grille of the fan and evaporator at regular intervals for conta...

Страница 40: ...ating system e g very hard water with too much mineral content If you are not sure refer to the installation technician see chap 8 Links Do not add any additives to the water in the heating systems In...

Страница 41: ...o measure the air pressure in the expansion tank air bag if the air pressure does not match the data on the expansion tank label refill the bag with air close drain valve 2 screw valve cover open ball...

Страница 42: ...nd remove the filter cover keep a cloth at hand less water will leak out remove filter rinse the filter remount the filter check for damage to the sealing ring on the filter cover screw the cover back...

Страница 43: ...outlet may not be fitted drain the water pressure with a hot water tap close the tap unscrew the anode the location is marked with the inscription in case of more than 50 decrease of magnesium anode...

Страница 44: ...gerant circuit see chapter 8 Links 7 Technical information in accordance with Commission Regulation EU No 813 2013 1 For heaters for heating interior spaces with a heat pump and combined heaters with...

Страница 45: ...limit temperature COPd 2 1 For air to water heat pumps Tj 15 C if TOL 20 C Pdh kW For air to water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 10 C For air to water heat pumps Opera...

Страница 46: ...on limit temperature COPd 2 1 For air to water heat pumps Tj 15 C if TOL 20 C Pdh kW For air to water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 10 C For air to water heat pumps Ope...

Страница 47: ...IR WATER Operation manual 45 8 Links In case of problems with internet connection please contact service visit the website of ACOND a s https tepelna cerpadla acond cz kontakt and click on the remote...