Acom 1006 Скачать руководство пользователя страница 10

 

 

N O T E  

If the characters on the LCD are dim or not readable, please follow the method of LCD contrast and back-
lighting adjustment described in S.5-1. 
 
In this position (called "OFF LINE" hereafter) only the micro-controller is operational, while the amplifier itself 
is still turned off (the tube is not powered at all). 
 
The control of the amplifier is accessible during "OFF LINE" and "ON LINE" states, each having several 
information screens and control functions (see Fig.3-2): 

POWER ON

 S.3

 

           
 
 
 

OFF LINE

 

S.5

                (ON/OFF 

S4.1

)               

ON LINE

 

S.4

 

                                                                                                                                                          
                                                                                                                                                          
                                                                        (NEXT or PREV)        (PREV+NEXT)               (PREV+NEXT) 
                                                                                                                                                       (+2sec)                   
                                                                        

INFORMATION 

S.4-4

                                                   

                                                                         Forward Power                                                           
                                                                         Reflected Power            

Tuning

 

S.4-3

             

LCD adj. 

S.5-1

        

(PREV+NEXT) 

 S.5-1

        (OPER) 

S.5-3

        Output Power                    TRI                                       

Contrast 

1...9   (PREV)           List of               Antenna VSWR                                                             

Back-light 

1...5 (NEXT)         Auto-Prot.           Drive RF Power                                               (PREV+NEXT) 

                                             

Signatures

           RF Power Gain                                           

Auto-Operate

 

S.5-2

 

                                         (PREV)--(NEXT)     Plate Current                        
(PREV+NEXT)  

S.5-2

                                      High Voltage 

Auto-Operate OFF

 (PREV)                              Plate RF Peak 

Auto-Operate ON

  (NEXT)                               Screen Current 

                                                                         DC Power Input  
                                                                         Exh. Air Temp. 
                                                                           

Fig.3-2 Information Screens and Control Functions Structure 

 
Use the OPER button to alternatively change between operate and standby modes (S.4-2) during "ON LINE". 
Please note that Auto-Operate might be enabled (see S.4-2). The same button activates signature list while "OFF 
LINE". 
 
The PREV and NEXT buttons change information screens or select control functions (S.4-4) for both "OFF 
LINE" and "ON LINE". 
 
The ON/OFF button alternatively switches OFF and "ON LINE". 
You can proceed in one of two directions: 
 
a) You can use the "OFF LINE" information screens and control functions. They refer to the auto-protection 
signatures list, LCD contrast and back-lighting control, as well as the Auto-Operate feature. This is described 
in S5. 
 
b) You can turn on the amplifier and begin the warm-up sequence. After 2.5 minutes you may tune and start 
operating the amplifier and you can use the "ON LINE" information screens or control functions (see below). 

4. OPERATION 

Operation of the amplifier is simplified due to the TRI tuning aid, Auto-Operate function, and automatic 
protection system, so you'll be able to begin using it immediately after the installation. However, to make full 
use of amplifier's potential and to fully configure it to your local conditions, we recommend that you thoroughly 
read the following information. 
 

Содержание 1006

Страница 1: ...6 m LINEAR AMPLIFIER OPERATING MANUAL ...

Страница 2: ... 2 3 Amplifier Location Selection 5 2 4 Connections 6 2 5 Installation of External Fan 8 3 POWER ON CONTROLS AND INDICATORS 8 4 OPERATION 9 4 1 Turning ON and OFF 10 4 2 Changing Operate and Standby Modes 10 4 3 Tuning 10 4 4 ON LINE Information Screens and Control Functions 12 4 5 Auto Protection System 13 5 OFF LINE OPERATION 13 5 1 Contrast and Back lighting control 13 5 2 Auto Operate enabling...

Страница 3: ...ning 14 6 2 Fuses Replacement 14 6 3 Tube Replacement 15 6 4 The ACOM1006 Simplified Schematic Diagram 15 6 5 Troubleshooting 16 7 SPECIFICATIONS 18 7 1 Parameters 18 7 2 Functions 18 7 3 Storage and Shipment 19 ...

Страница 4: ... the amplifier in operate mode for you thus saving manual operations and time No heavy outboard antenna tuners required for antenna VSWR up to 3 1 Your amplifier will perform the functions of an antenna tuner thus enabling you to change antennas faster and use them over a wider frequency range saving tuning time An amplifier that is both user friendly and that looks after itself It is designed to ...

Страница 5: ...red yellow with two green stripes and the grounding stud on the rear panel of the amplifier marked GND must be connected to the station s grounding system for safe operation The amplifier is designed to meet international safety standards and complies with CE safety and electromagnetic compatibility requirements as well as FCC regulations This operating manual contains information precautions and ...

Страница 6: ...inspect the cardboard carton and its contents for physical damage If damage is noticed notify your dealer immediately Delay may infringe carrier s warranty conditions Keep all packing for possible future transportation 2 2 Line Voltage Selection C A U T I O N To avoid damage not covered under warranty check carefully if the voltage for which the amplifier is set corresponds to your mains nominal v...

Страница 7: ...age drop on it Therefore it may be necessary to improve it considerably i e to become less resistive with heavier wires and lower resistive ground path The grounding wires should be at least 8sq mm AWG 8 or SWG 10 a First connect the ground stud of the amplifier on the rear panel marked GND to the station s grounding system Fig 2 1 b Connect a coaxial cable with a PL 259 plug from the transceiver ...

Страница 8: ... dealer If your transceiver does not have such an input don t worry the amplifier contains an independent self protection for the antenna relay It looks after the T R switching to be safe regardless of taking or not advantage of the KEY OUT possibility so the amplifier will function normally and the KEY OUT may remain unused as well The output KEY OUT of the amplifier is an open drain circuit and ...

Страница 9: ...NTROLS AND INDICATORS C A U T I O N Do not turn the amplifier on for at least 2 hours after unpacking it in the room where it will be used Pay particular attention when you move it from a very cold into a very warm place since condensation is likely A similar effect can occur after a rapid warming of the operating room for instance after switching on a powerful heater in a cold room In such a case...

Страница 10: ...re Use the OPER button to alternatively change between operate and standby modes S 4 2 during ON LINE Please note that Auto Operate might be enabled see S 4 2 The same button activates signature list while OFF LINE The PREV and NEXT buttons change information screens or select control functions S 4 4 for both OFF LINE and ON LINE The ON OFF button alternatively switches OFF and ON LINE You can pro...

Страница 11: ...de instead of turning it off By repeatedly turning the heater voltage on and off the tube life is shortened However if you unintentionally power off the amplifier it is best to switch it on again immediately When the pause is short up to 1 minute and the cathode is still warm the warm up period is shortened significantly which reduces the waiting time and prolongs the tube s expected life After th...

Страница 12: ...antenna BEFORE the next step Retune after selecting a different antenna since both impedances may differ substantially unless their VSWR is excellent i e below 1 1 1 for both C A U T I O N When tuning do not apply continuous drive longer than 3 minutes and after that pause 1 2 minutes for tube cooling We recommend that you tune up at the center frequencies of the preferred frequency segment First ...

Страница 13: ... both tunings would be virtually independent This is a benefit of the TRI The plate load resistance increases to the right and decreases to the left of the TRI center The center of the scale corresponds to the proper LOAD capacitor tuning which presents an optimum load resistance to the tube If you tune to the right you ll obtain more gain but less undistorted output power will be attainable You m...

Страница 14: ... off mode Auto Protection You ll get the corresponding signature see S 6 5 Troubleshooting If you cannot guess what the reason is you may try to turn the amplifier on again in order to check whether it s not an accidental condition If the problem persists you ll need to contact your dealer see S 1 2 N O T E The 6dB input attenuator is automatically inserted about 1 second after a bad tuning is det...

Страница 15: ... event nr 1 is the last nr 7 is the oldest one A and B mark the first and the second part of an information screen pair Two lines three groups by six symbols 36 symbols in total are to be copied concerning every one of the 7 memorized events from 1A 1B through 7A 7B To decode the signatures please see S 6 5 Troubleshooting N O T E After every signature listing the tube warm up time is reset to 150...

Страница 16: ...or DC plate voltage is fed through chokes RFC1 RFC2 and the capacitor Cb3 blocks it from the output The output circuit comprises LP LL CP and CL1 CL2 which form a classic Pi L network and suppress the harmonic frequency emissions This tank is tuned over the band by the air variable capacitors CP and CL1 The output signal is fed through an additional VHF low pass filter for frequencies above 55MHz ...

Страница 17: ...16 Fig 6 1 ACOM1006 Simplified Schematic Diagram ...

Страница 18: ...s in brackets below are the signal names designations according to the CONTROL PCB electrical schematic diagram and signal type 1 peak forward power pfwd analogue 2 reflected power rfl analogue 3 input drive power inp analogue 4 peak anode alternate voltage paav analogue 5 screen grid current g2c analogue 6 plate current ipm analogue 7 high voltage hvm analogue 8 exhaust air temperature temp analo...

Страница 19: ...onse less than 0 5dB 50 to 60W drive power for rated output h Primary Power 85 264V 100 110 120 200 210 220 230 240V nominal taps 10 15 tol 50 60Hz single phase 2200VA consumption at rated output i Complies with CE safety and electromagnetic compatibility requirements as well as FCC regulations j Size Weight operating W422mm x D355mm x H182mm 22kg k Operating environments Temperature range 0 50 de...

Страница 20: ...C A U T I O N Should you need to transport the amplifier use the original packing as described below First switch off the amplifier Pull the mains plug out of the outlet Disconnect all cables from the rear panel of the amplifier remove the ground connection the last Finally pack the amplifier in its original carton a Storage environments the amplifier can be kept packed in dry and ventilated unhea...

Отзывы: