ECOJET GREASE SEPARATOR - Installation guide | Kate Jennings
5
Each separator is supplied with a sticker on each side identifying the separator and size.
4
INSTALLATION
The EcoJet grease separator must be installed in compliance with local water authority
regulations, Safework Australia and all other codes of practice. Prior to installation,
ensure that the local water authority approves each installation.
The grease separator should be installed on level concrete.
Before using the grease separator for the first time, fill with clean water.
4.1 Location
Ensure the location of the grease separator is positioned where a maintenance contractor
can easily access for pump out. If in doubt, contact a grease removal contractor and
obtain a written agreement that the grease separator is able to be serviced.
All above ground grease separators require steps and a platform for maintenance
purposes, in accordance with AS 1657-1992.
4.2 Connecting pipes
Connecting pipes and pipe materials should be installed in accordance with AS 3500 and
local plumbing codes.
*IO: Inspection Opening
*TWSP: Trade Waste Sampling Point
I.O
I.O / TWSP
Vent