RMC 7152
14” short depth server
RMC 7152
14” short depth server
61
RMC 7152
14” short depth server
XSet LAN Configuration
Set this feature to configure the IPMI LAN adapter with a network address as shown in the following graphics.
Channel Number - Enter the channel number for the SET LAN Config com- mand. This is initially set to [01]. Press "+" or "-"
on your keyboard to change the Channel Number.
Channel Number Status - This feature returns the channel status for the Channel Number selected above: "Channel
Number is OK" or "Wrong Channel Number".
IP Address Source
Select the source of this machine's IP address. If Static is selected, you will need to know and enter manually the IP address
of this machine below. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Configuration Protocol) server in
the network it is attached to, and request the next available IP address. The options are DHCP and Static.
The following items are assigned IP addresses automatically if DHCP is selected under IP Address Source above:
IP Address
Enter the IP address for this machine. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). The value of
each three-digit number separated by dots should not exceed 255 as shown in the screen below.
Subnet Mask
Subnet masks tell the network which subnet this machine belongs to. The value of each three-digit number separated by
dots should not exceed 255.
Gateway Address
This is the IP address of the gateway in the network. This is usually a router.
Mac Address
The BIOS will automatically enter the Mac address of this machine; however it may be over-ridden. Mac addresses are 6 two-
digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e., 00.30.48.D0.D4.60).
XSET PEF Configuration
PEF Support
Select Enabled to enable the function of Platform Event Filter (PEF) which will interpret BMC events and perform actions
based on pre-determined settings or events and performs actions based on pre-determined settings or 'traps' under IPMI 1.5
specifications. For example, powering the system down or sending an alert when a triggering event is detected. The default is
Disabled.
The following will appear if PEF Support is set to Enabled.
PEF Action Global Control (Available if the item-PEF Support is enabled)
These are the different actions based on BMC events. The options are Alert, Power Down, Reset System, Power Cycle,
OEM Action, Diagnostic Interface.
Alert Startup Delay (Available if the item-PEF Support is enabled)
This feature inserts a delay during startup for PEF alerts. The options are En- abled and Disabled.
Startup Delay (Available if the item-PEF Support is enabled)
This feature enables or disables startup delay. The options are Enabled and Disabled.
BMC Watch Dog Timer Action