4.6 Power On after Power Failure
This option defines the system’s behavior when DC power is supplied.
Value
Description
S0 – Power On
System is powered on when DC power is supplied.
S5 – Power Off
System is kept in off state when DC power is supplied.
Last State
Last system operating state when DC power loss occurred.
When you want to use the AT-mode remote on/off control function, you have to set
this option to “S0 – Power On”. Please refer to
for instructions of using AT-mode remote on/off control function.
To set “Power On after Power Failure” option:
1. Press
F2
when the system boots up to enter the BIOS setup utility.
2. Go to
[Power]
.
3. Set the
[Power On after Power Failure]
option to the desired setting.
4. Once set, press
F10
to save setting and exit.
70