the retina if you take a close look at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX controller)
and let the unit run at least five minutes to cool down before switching off the mains
supply. Never handle the lamp or luminary when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection
5.3 Change The Lamp
Do not use this lamp more than 3000 hours, Using the lamp any longer than its set life could
seriously damage your unit. Periodically checking the lamp running time, when the lamp reaches
the 3000 hour mark, or close to it, we strongly suggest you switch the lamp out. Clear the RESET
TIME after you have replaced the lamp.
1. Remove the fixture head covers using a screwdriver (Figure 1).
Figure 1
A
8B