5A 

10

 

Microphone: 

Receive music for the sound active. 

11   DMX input:

 For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal.

 

12   DMX output: 

For DMX512 link, use 3/5-pin XLR plug cable to link the next unit.

 

13   Only for remote control: 

By connect to the CA-8 or CA-9 RTX to control the unit for Stand by, 

Function and Mode function. 

14   Safety Ring: 

For attached the safety cable. 

15   Mains output: 

Connect to supply mains power for the next unit.

 

16   Mains input: 

Connect to supply mains power.

 

4.2Main Function   

To select any of the given functions, press the 

MENU

 button to show the required option on the 

display. Select the function with the 

ENTER

 button and the display will blink. Use the 

DOWN

 and 

UP

 buttons to change the mode. Once the required mode has been selected, Press the 

ENTER

 

button to store. To go back to the main menu without any changes press the

 MENU

 button. Hold 

and press the 

MENU

 button about one second or wait for one minute to exit the menu mode. The 

main functions are shown below: 

 

 

 

Содержание VENOM LED-460

Страница 1: ...VENOM LED 460 User Guide Please read the instruction carefully before use...

Страница 2: ...Set the Fixture 4 4 1 Control Panel 4 4 2Main Function 5 5 How to Control the Unit 9 5 1 Master Slave Built In Preprogrammed Function 9 5 2 Easy Controller by CA 8 10 5 3 DMX Controller 10 6 DMX 512 C...

Страница 3: ...uch any wire during operation and there might be a hazard of electric shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The housing must be...

Страница 4: ...Hz Power consumption 38 9W Fuse T 6 3A LED 6 x 3W Tri color LEDs 30000hrs rated Dimension 424 x 251 x 138mm Weight 3 8kgs 3 Installation The unit should be mounted via its screw holes on the bracket A...

Страница 5: ...4 1 Control Panel 1 Display To show the various menus and the selected functions LED 2 DMX On DMX input present 3 MASTER On Master Mode 4 SLAVE On Slave Mode 5 SOUND Flashing Sound activation Button 6...

Страница 6: ...ect to supply mains power for the next unit 16 Mains input Connect to supply mains power 4 2Main Function To select any of the given functions press the MENU button to show the required option on the...

Страница 7: ...6A...

Страница 8: ...ons without any change press the MENU button Show Mode Press the MENU button up to when the is shown on the display Pressing the ENTER button Use the DOWN and UP button to select the Random show or sh...

Страница 9: ...ink Use the DOWN and UP button to select display on or display off mode Once selected press the ENTER button to setup or exit menu mode without any change after 60 seconds Back to the functions withou...

Страница 10: ...rogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated synchronized light show This function is good when y...

Страница 11: ...on the display Press the ENTER button and the display will blink Use the DOWN and UP buttons to change the DMX512 address Once the address has been selected press the ENTER button to store To return t...

Страница 12: ...11A 6 DMX 512 Configuration 3 Channels Mode 7 Channels Mode...

Страница 13: ...12A 18 Channels Mode 7 DMX 512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels...

Страница 14: ...n address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin...

Страница 15: ...ing the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of conditio...

Страница 16: ...nce with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 200...

Страница 17: ...16A Innovation Quality Performance...

Отзывы: