ACME STAGE PAR 400 ZOOM IP Скачать руководство пользователя страница 17

9 Channels mode: 

CHANNEL 

VALUE 

FUNCTION 

 

000-255 

RED 

0%

100% 

 

000-255 

GREEN 

0%

100% 

 

000-255 

BLUE 

0%

100% 

 

000-255 

WHITE 

0%

100% 

 

000-255 

DIMMER 

0%

100% 

000-255 

DIMMER FINE 

 

000-014 
015-042 
043-070 
071-078 
079-106 
107-114 
115-142 
143-150 
151-178 
179-186 
187-214 
215-222 
223-250 
251-255 

STROBE 

Open 

Strobe from fast to slow 

Pulse from fast to slow 

Random Strobe 

Burst from fast to slow 

Random burst 

Burst pulse from fast to slow 

Random burst pulse 

Slow open Fast close 

Random slow open fast close 

Fast open Slow close 

Random fast open slow close 

Slow open slow close 

Open 

 

000-255 

ZOOM 

40°

6° 

 

000-009 
010-014 
015-019 
020-024 
025-029 
030-034 
035-039 
040-044 
045-049 
050-054 
055-059 

Macro Color For All LED 

Open (RGBW color mixing enabled) 

LEE 790 – Moroccan pink 

LEE 157 – Pink 

LEE 332 – Special rose pink 

LEE 328 – Follies pink 

LEE 345 – Fuchsia pink 

LEE 194 – Surprise pink 

LEE 181 – Congo Blue 

LEE 071 – Tokyo Blue 

LEE 120 – Deep Blue 

LEE 079 – Just Blue 

 

16G 

Содержание STAGE PAR 400 ZOOM IP

Страница 1: ......

Страница 2: ...cal Specifications 4 3 How To Set The Fixture 5 3 1 Control Panel 5 3 2 Main Functions 6 4 How To Control The Unit 13 4 1 DMX512 Controller 14 4 2 DMX512 Configuration 14 4 3 DMX512 Connection 18 5 Tr...

Страница 3: ...ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power su...

Страница 4: ...tion Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the original packing materials be...

Страница 5: ...channels Control Mode DMX512 RDM Firmware Upgrade via DMX link Construction Display OLED display Data In Out 5 pin IP XLR Power In Out Waterproof Power Connector in out Protection Rating IP66 Feature...

Страница 6: ...Dimensions Weight 295x316x318mm 8 5kgs 11 6 x12 4 x12 5 in 18 7lbs Photometrics Diagram 3 How To Set The Fixture 3 1 Control Panel 5G...

Страница 7: ...pply power 6 POWER OUT Connects to the next fixture 3 2 Main Functions Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is shown on the mo...

Страница 8: ...7G...

Страница 9: ...To select DMX State press the ENTER button to confirm use the UP DOWN button to select Last State Blackout or Show Fixture Setting To select Fixture Setting press the ENTER button to confirm use the U...

Страница 10: ...l is coarser at low levels and finger at high levels S Curve Light intensity control is finger at low levels and high levels and coarser at medium levels Dimmer Speed To select Dimmer Speed press the...

Страница 11: ...me To select Fade Time press the ENTER button to confirm Use the UP DOWN button to adjust the value from 0 to 255 Press the MENU button back to the last menu or let the unit idle 30 seconds to exit me...

Страница 12: ...on back to the last menu or let the unit idle 30 seconds to exit menu mode Temperature Unit Select Temperature Unit press the ENTER button to confirm present mode will blink on the display use the UP...

Страница 13: ...to exit Firmware Version Select Firmware Version press the ENTER button to confirm firmware version will show on the display press the MENU button back to exit RDM UID Select RDM UID press the ENTER...

Страница 14: ...menu and the program version number of the fixture will be displayed Select the DMX START ADDRESS menu to change the DMX 512 address 001 512 Select the DEVICE MODEL DESCRIPTION menu to display the mo...

Страница 15: ...k to the last menu or let the unit idle 30 seconds to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Addre...

Страница 16: ...043 070 071 078 079 106 107 114 115 142 143 150 151 178 179 186 187 214 215 222 223 250 251 255 STROBE Open Strobe from fast to slow Pulse from fast to slow Random Strobe Burst from fast to slow Rand...

Страница 17: ...fast to slow Random burst Burst pulse from fast to slow Random burst pulse Slow open Fast close Random slow open fast close Fast open Slow close Random fast open slow close Slow open slow close Open...

Страница 18: ...ll CT Blue LEE 202 Half CT Blue LEE 117 Steel Blue LEE 353 Lighter Blue LEE 118 Light Blue LEE 116 Medium Blue Green LEE 124 Dark Green LEE 139 Primary Green LEE 089 Moss Green LEE 122 Fem Green LEE 7...

Страница 19: ...damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when on...

Страница 20: ...her DMX controller 5 Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working...

Страница 21: ...20G...

Страница 22: ...21G...

Страница 23: ...ars CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 2014 30 EU EN 55032 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55103 2 2009 Harmonized Standard EN 6059...

Страница 24: ...Innovation Quality Performance...

Отзывы: