ACME Stage Par 220MP-220 Скачать руководство пользователя страница 4

 

3- 

y

  Do not allow children to operate the fixture. 

y

  Do not touch any wire during operation as there might be a hazard of electric shock. 

y

  Avoid power wires together around other cables. 

y

  Disconnect mains power before fuse/lamp replacement or servicing. 

y

  Replace fuse only with the same type. 

y

  In the event of serious operating problem, stop using the unit immediately.   

y

  Never turn on and off the unit time after time. 

y

  The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly 

damaged. 

y

  Do not open the unit as there are no user serviceable parts inside. 

y

  Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead 

to damage or malfunction. Please contact the nearest authorized technical assistance 

center.  

y

  Disconnect the mains power if the fixture is not used for a long time. 

y

  Do use original packing materials once transport it again. 

y

  Do not look directly at the LED light beam while the fixture is on. 

y

  Possibly hazardous optical radiation emitted from this product. 

 

Installation  

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit 

is firmly fixed to avoid vibration and slipping while operating. Always ensure that the 

structure to which you are attaching the unit is secure and is able to support a weight of 10 

times of the unit’s weight. Also always use a safety cable that can hold 12 times of the 

weight of the unit when installing the fixture.   

The equipment must be fixed by professionals. And it must be fixed at a place where is out 

of the touch of people and has no one pass by or under it. 

 

 

 

 

 

 

 

 

 

12- 

5. DMX512 Configuration   

 

Mode 4&5

 

 

 

Mode 7: 

 

 

Содержание Stage Par 220MP-220

Страница 1: ...15 Innovation Quality Performance Stage Par 220 MP 220 User Manual Please read the instructions carefully before use ...

Страница 2: ...blems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 1 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check m...

Страница 3: ...erate follow up the user manual artificial fault are not under guarantee repair y Unpack and check carefully that there is no transportation damage before using the unit y The unit is for indoor use only Use only in a dry location y Do install and operate by operator y Use safety chain when fixes the unit Don t handle the unit by taking its head only but always by taking its base y The unit must b...

Страница 4: ...arest authorized technical assistance center y Disconnect the mains power if the fixture is not used for a long time y Do use original packing materials once transport it again y Do not look directly at the LED light beam while the fixture is on y Possibly hazardous optical radiation emitted from this product Installation The unit should be mounted via its screw holes on the bracket Always ensure ...

Страница 5: ... Slave1 or Slave 2 on the second unit to get contrast movement to each other even if you have two units only 4 2 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button ...

Страница 6: ... color Press the MENU button up to when is shown on the display Pressing the ENTER button and use the DOWN and UP buttons to select or or strobe press the ENTER button to confirm and use the DOWN and UP buttons to adjust the value between 0 and 255 once selected press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function witho...

Страница 7: ...wn on the display Pressing the ENTER button and the display will blink Use the DOWN and UP buttons to select display always on or display off 20 seconds after exit menu mode Once selected press the ENTER button to setup or exit menu mode without any change after one minute Back to the functions without any change press the MENU button again Display Inverse Press the MENU button until is blinking o...

Страница 8: ...fade if you select the color or fade mode press the ENTER button to confirm and use the DOWN and UP buttons to select color 1 10 or fade speed speed 1 slow speed 2 middle speed 3 fast Once selected press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button 8 Dimmer Mode Press the MENU ...

Отзывы: