background image

066 ~ 076 

077~ 087 

088 ~ 098 
099 ~ 109 
110 ~ 120 
121 ~ 127 

 

128~ 187 

188 ~ 196 
197 ~ 255 

Color 3 

Color 3 

 Color 4 

Color 4 

Color 4 

 Color 5 

Color 5 

Color 5 

 Open 

Continuous Rotation 

CW Rotation: fast 

 slow 

Stop 

CCW Rotation: slow 

 fast 

 

 

4.5 DMX512 Connection   

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels. 

 

 

 

 

 

 

 

1.

 

If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. 

2.

 

The  last units  DMX cable has to be terminated with a 120 ohm 1/4W resistor between pin 

2(DMX-) and pin 3(DMX+) of a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 

3.

 

Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the 

ATTENTION 

 

Termination reduces signal errors and to avoid signal transmission problems 

and interference. It is always advisable to connect a DMX terminal (Resistance 

120 ohm 1/4W between pin2 (DMX-) and pin3 (DMX+) of the last fixture). 

 

 

12B 

Содержание LED WAVE 100

Страница 1: ...LED WAV 100W User Manual Please read the instruction carefully before use ...

Страница 2: ...1 Control Panel 4 3 2 Lens Installation 5 3 3 Main Function 6 4 How To Control The Unit 10 4 1 Master Slave Built In Preprogrammed Function 10 4 2 Easy Controller 10 4 3 DMX Controller 11 4 4 DMX 512 Configuration 11 4 5 DMX512 Connection 12 5 Troubleshooting 13 6 Fixture Cleaning 14 1B ...

Страница 3: ...ls close to the unit while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 75 DO NOT touch the housing bare hand during its operation Turn off the power and allow a...

Страница 4: ...the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals It must be installed in a place where is out of the reach of people and no one can pass by or under it 2 Technical S...

Страница 5: ... 100W cold white LED Weight 6 2Kgs Dimension 309 x 271 x 210 mm 3 How To Set The Unit 3 1 Control Panel 3 1 Only for remote control Connects to optional CA 8 to control the unit in Stand by Function and Strobe Blackout modes 2 DMX IN DMX512 link use 3 pin XLR cable to link the unit and the DMX controller 3 DMX OUT 4B ...

Страница 6: ...kward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions 9 Function Display To show the various menus and the selected functions 3 2 Lens Installation A Product Items User manual 29 lens B Mounting You can install the unit on the truss or ceiling Use clamps to fix the unit to truss Always ensure that the unit is firmly fixed to avoid vibrat...

Страница 7: ...e far slot is for 44 lens 3 3 Main Function To select any of the given functions press the MENU button up to when the required selection as shown on the display Select the function by the ENTER button and the display will blink Use the DOWN UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any change press the ...

Страница 8: ... ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically exit menu mode without any change after one minute Back to the previous functions without any change press MENU button 7B ...

Страница 9: ...e 1 or set the fixture as slave 2 Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button again Display Inverse Press MENU button until is blinking on the display Use DOWN and UP button to select display normal or display inverse press ENTER...

Страница 10: ...o the functions without any change press MENU button Temperature Test Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button again Fixture Hours Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the numb...

Страница 11: ...ure will allow you to link 2 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect need to set as master and the other unit need to set as slave 1 via menu then the first unit will control the other to give an automatic and synchronized light show This function is good when you want an instant show Any fixture can ac...

Страница 12: ...TER button pressed up to when the display stops blinking or storing automatically one minute later To go back to the functions without any change press the MENU button again If you use please refer to the following diagram to address your DMX512 channel for the first 4 units 3 channels 4 4 DMX 512 Configuration 3 Channel Mode CHANNEL VALUE FUNCTIONS 1 000 255 DIMMER 0 100 2 000 009 010 120 121 134...

Страница 13: ... pins DMX output you need to use a 5 to 3 pin adapter cable 2 The last units DMX cable has to be terminated with a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX of a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the ATTENTION Termination reduces signal errors and to avoid signal transmis...

Страница 14: ... pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 Pin 5 Not used 5 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LE...

Страница 15: ...t mode E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 6 Fixture Cleaning The cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding...

Страница 16: ...ision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance ...