background image

 

 

 

 

 

 

 

LED-SC252 

 
 
 

 

                                    User  Manual

Please read the instruction carefully before use

 

Содержание LED-SC252

Страница 1: ...LED SC252 User Manual Please read the instruction carefully before use ...

Страница 2: ...ns 3 3 How To Set The Unit 4 3 1 Control Panel 4 4 How To Control The Unit 5 4 1 Master Slave Built In Preprogrammed Function 5 4 2 Easy Controller 6 4 3 DMX Controller 6 5 DMX 512 Configuration 7 6 DMX512 Connection 9 7 Troubleshooting 11 8 Fixture Cleaning 12 ...

Страница 3: ...rials close to the unit while operating as it is fire hazard Use safety cables when fixing this unit Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than this Turn off the power and allow about 15 minutes for the unit to cool down before servicing In the event of a serious operating problem stop using the unit immediately Never try to repair the uni...

Страница 4: ...ng the fixture The equipment must be installed by professionals It must be fixed at a place where is out of the reach of people and no one pass by or under it 2 Technical Specifications Featuring 1 8 stepping motors latest LED technology the Dynamic 25 Dual Scan delivers outstanding active effects 10 DMX channels pan tilt gob strobe dimmer for each head Gobo color wheel with 8 gobos colors plus op...

Страница 5: ...4A LED Sources 2 25W CREE LEDs Beam Angle 16 Weight 6 5Kgs Dimension 351 283 231mm 3 How To Set The Unit 3 1 Control Panel ...

Страница 6: ...E T 3 15A Protects the unit from over voltage or short circuit 8 POWER OUT Connects to the next fixture 9 POWER IN Connects to power supply 4 How To Control The Unit You can operate the unit in three ways 1 Master slave built in preprogram function 2 Easy controller optional CA 8 3 Universal DMX controller You do not need to turn the unit off when you change the DMX address the new DMX address set...

Страница 7: ... the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show 4 2 Easy Controller The easy CA 8 remote control is used only in master slave mode By connecting to the 1 4 jack socket of the first unit You will find that the remote control in the first unit will control all the other units f...

Страница 8: ...256 2 Light Show Examples 10 CH mode Dip switch 10 ON Channel 1 dip on 1 1 Channel 2 dip on 1 2 4 1 2 8 11 Channel 3 dip on 1 3 5 1 4 16 21 Channel 4 dip on 1 2 3 4 5 1 2 4 8 16 31 5 DMX 512 Configuration 10 Channels Mode CHANNEL VALUE FUNCTION 1 0 255 PAN 1 0 180 2 0 255 TILT 1 0 70 3 0 7 8 15 16 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 STROBE 1 Blackout Open Strobe slow fast O...

Страница 9: ...g Gobo 3 shaking Gobo 4 shaking Gobo 5 shaking Gobo 6 shaking Gobo 7 shaking Gobo 8 shaking Gobo rotation slow fast 5 0 255 DIMMER 1 0 100 6 0 255 PAN 2 0 180 7 0 255 TILT 2 0 70 8 0 7 8 15 16 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 STROBE 2 Blackout Open Strobe slow fast Open Fast open slow close Open Fast close slow open Open Random strobe Open 9 0 7 8 14 15 21 22 28 29 35 GO...

Страница 10: ...bo 6 Gobo 7 Gobo 8 Open shaking Gobo 1 shaking Gobo 2 shaking Gobo 3 shaking Gobo 4 shaking Gobo 5 shaking Gobo 6 shaking Gobo 7 shaking Gobo 8 shaking Gobo rotation slow fast 5 0 255 DIMMER 2 0 100 6 DMX512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels ...

Страница 11: ... signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal 4 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 5 Each fixture unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of...

Страница 12: ...problems check the cables on connectors 4 Try to another DMX controller 5 Check if the DMX cables run near or run alongside high voltage cables that may cause interference to DMX circuits C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the unit Set the proper address D ...

Страница 13: ...requency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 30 days ...

Страница 14: ...13A ...

Страница 15: ...ith the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Страница 16: ...15A Innovation Quality Performance ...

Отзывы: