ACME LED-MB8FC Скачать руководство пользователя страница 3

 
                                                                                     

 

2A

 

1.

 

Safety

 

Instructions

   

 

WARNING

 

 

y

 

PLEASE

 

keep

 

this

 

User

 

Manual

 

for

 

future

 

consultation.

 

If

 

you

 

sell

 

the

 

fixture

 

to

 

another

 

user,

 

make

 

sure

 

that

 

they

 

also

 

receive

 

this

 

instruction

 

booklet.

 

y

 

PLEASE

 

unpack

 

and

 

check

 

carefully

 

there

 

is

 

no

 

transportation

 

damage

 

before

 

using

 

the

 

fixture.

 

y

 

It’s

 

important

 

to

 

ground

 

the

 

yellow/green

 

conductor

 

to

 

earth

 

in

 

order

 

to

 

avoid

 

electric

 

shock.

 

y

 

PLEASE

 

disconnect

 

mains

 

power

 

before

 

servicing

 

and

 

maintenance.

 

y

 

Maximum

 

ambient

 

temperature

 

is

 

Ta:

 

40

.

 

DO

 

NOT

 

operate

 

it

 

where

 

the

 

temperature

 

is

 

higher

 

than

 

this.

 

y

 

Unit’s

 

surface

 

temperature

 

may

 

reach

 

up

 

to

 

85

.

 

DO

 

NOT

 

touch

 

the

 

housing

 

bare

handed

 

during

 

its

 

operation.

 

y

 

In

 

the

 

event

 

of

 

serious

 

operating

 

problem,

 

stop

 

using

 

the

 

fixture

 

immediately.

 

Never

 

try

 

to

 

repair

 

the

 

fixture

 

by

 

yourself.

 

Repairs

 

carried

 

out

 

by

 

unskilled

 

people

 

can

 

lead

 

to

 

damage

 

or

 

malfunction.

 

Please

 

contact

 

the

 

nearest

 

authorized

 

technical

 

assistance

 

center.

 

Always

 

use

 

the

 

same

 

type

 

spare

 

parts.

 

y

 

DO

 

NOT

 

connect

 

the

 

device

 

to

 

any

 

dimmer

 

pack.

 

y

 

DO

 

NOT

 

touch

 

any

 

wire

 

during

 

operation

 

and

 

there

 

might

 

be

 

a

 

hazard

 

of

 

electric

 

shock.

 

y

 

The

 

housing

 

must

 

be

 

replaced

 

if

 

they

 

are

 

visibly

 

damaged.

 

Warning

 

y

 

To

 

prevent

 

or

 

reduce

 

the

 

risk

 

of

 

electrical

 

shock

 

or

 

fire,

 

do

 

not

 

expose

 

the

 

unit

 

to

 

rain

 

or

 

moisture.

 

y

 

The

 

housing,

 

the

 

lenses,

 

or

 

the

 

ultraviolet

 

filter

 

must

 

be

 

replaced

 

if

 

they

 

are

 

visibly

 

damaged.

 

 

 

 

 

For

 

230V

 

50Hz

 

power

 

supply,

 

maximum

 

fixtures

 

that

 

can

 

be

 

connected

 

together

 

from

 

the

 

same

 

mains

 

outlet

 

is

 

8pcs;

 

For

 

120V

 

60Hz

 

power

 

supply,

 

maximum

 

fixtures

 

that

 

can

 

be

 

connected

 

together

 

from

 

the

 

same

 

mains

 

outlet

 

is

 

5pcs;

 

Please

 

read

 

the

 

instructions

 

carefully

 

which

 

includes

 

important

 

information

 

about

 

the

 

installation,

 

operation

 

and

 

maintenance.

 

Содержание LED-MB8FC

Страница 1: ...LED MB8FC User Manual Please read the instruction carefully before use...

Страница 2: ...t The Unit 4 3 1 Front Rear Panel 4 3 2 Main Function 5 4 How to Control the Unit 10 4 1 Master Slave Built In Preprogrammed Function 10 4 2 Easy Controller 11 4 3 DMX Address Setting 11 5 DMX512 Conf...

Страница 3: ...the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts...

Страница 4: ...ixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications y Innovative moving heads delivering marvelous l...

Страница 5: ...6mm 3 How To Set The Unit 3 1 Front Rear Panel 1 Function Display Used to show the various menus and the selected functions 2 LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOU...

Страница 6: ...over current 7 DMX IN OUT For DMX512 links use 3 pin XLR plug cable to link the unit together 3 2 Main Function To select any functions press the MENU button until the required function is showing on...

Страница 7: ...6A...

Страница 8: ...ode Slave Mode To select the Slave Mode press the ENTER button to show SLAVE MODE on the display Use the DOWN UP button to select the Master Slave 1 or Slave 2 modes Once the mode has been selected pr...

Страница 9: ...On LED on or Off LED off mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold and press the MENU butto...

Страница 10: ...ute to exit the menu mode Auto Test To select the Auto Test press the ENTER button to show AUTO TEST on the display and the unit will run a self test To go back to the functions without any changes pr...

Страница 11: ...e the DMX address as new DMX address setting will be affected at once Each time you turn the unit on it will show MB8FC on the display After that the unit will be ready to receive DMX signal or run th...

Страница 12: ...Use the DOWN and UP button to change the DMX address Once the address has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold...

Страница 13: ...12A 5 DMX512 Configuration 1 7 Channels Mode...

Страница 14: ...13A 13 Channels Mode...

Страница 15: ...14A 37 Channels Mode...

Страница 16: ...15A...

Страница 17: ...to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor be...

Страница 18: ...check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause...

Страница 19: ...lly y Clean the external optics at least every 30 days Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordanc...