background image

 

 

3- 

2. Technical Specification   

  Featuring  4  LED  clusters  &  great  programs,  styled  rocks  the  crowds  with  dynamic 

scanning effects and powerful beams. 

  3 Operation Modes: DMX, Master/Slave, Sound Activation. 

  Optional CA-8 easy controller for enjoying instant lighting shows at your fingertips. 

  Low heat, low power consumption; No duty cycle, run all night. 

  Dip-switch for setting DMX address. 

  Perfect for discos, clubs, pubs, parties and mobile DJs. 

 

 

Voltage:

 AC 100V~240V 50/60Hz 

 

Fuse:

 T 6.3A 

 

Power Consumption: 

12W 

 

LED: 

total: 256, Red: 96pcs, Green: 96pcs, Blue: 64pcs 

 

Dimension:

 965 x 190 x 185mm 

 

Weight:

 6.3kgs 

 

 

 

 

 

 

3. Installation   

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is 

firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure 

to which you are attaching the unit is secure and is able to support a weight of 10 times of 

the unit

’s weight. Also always use a safety cable that can hold 12 times of the weight of the 

unit when installing the fixture.   

The equipment must be fixed by professionals. And it must be fixed at a place where is out 

of the touch of people and has no one pass by or under it. 

 

 
 
 
 

Содержание LED-7474

Страница 1: ...STYLED LED 7474 User Manual Professional Entertainment Technolog...

Страница 2: ...echnical Specification 3 Installation 4 How to Control the Unit 4 1 Control Panel 4 2 Master Slave operation 4 3 Easy controller CA 8 4 4 Universal DMX controller 5 DMX 512 Configuration 6 DMX 512 Con...

Страница 3: ...pe spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of electric shock To prevent or reduce the risk of electrical shock or fi...

Страница 4: ...onsumption 12W LED total 256 Red 96pcs Green 96pcs Blue 64pcs Dimension 965 x 190 x 185mm Weight 6 3kgs 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that...

Страница 5: ...ip switches For different function setting 4 2 Master Slave Operation The unit can be linked together in daisy chain as many as you need in master slave mode to perform the great built in pre programm...

Страница 6: ...switches from 1 to 9 to make sure all the units will receive its DMX signal The dip switch 10 is used to choose channel mode Please refer to the following diagram to know how to address your DMX 512...

Страница 7: ...6 Set dip switch 10 to OFF the unit is in 6 channels mode Unit 1 dip on 1 1 Unit 2 dip on 1 2 3 1 2 4 7 Unit 3 dip on 1 3 4 1 4 8 13 Unit 4 dip on 1 2 5 1 2 16 19 5 DMX 512 Configuration 1 6 CH modes...

Страница 8: ...branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables solder joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX ou...

Страница 9: ...ms check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cau...

Страница 10: ...equency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using no...

Страница 11: ...dance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN610...

Страница 12: ...11 Innovation Quality Performance...

Отзывы: