16B
Stand by
Blackout the unit
Function
Strobe
1. Color sync. strobe
2. Sync. strobe
3. Two-light strobe
X/Y moving show pattern
selection
( Show 1 ~ Show 4 )
Please refer to 4.2. Main
Functions- Show mode
Gobo/Color
selection
1.Hold on for gobo
selection
2.Press for color
change
X/Y moving setting
1.Pan position
2.Tilt position
3.Dimmer
First set Master unit, then set Slave
units’ position
Mode
Sound 1
(LED off )
Sound 2
(LED slow blinking)
Slow/Sound 3
(LED on)
Position/ Latch
(LED fast blinking)
5.3.1 iSolution Operation
·
Consistent DMX configuration enable iMove to be linked with iRock and iShow together
and controlled at the same time.
·
DMX address can be set remotely by iLead controller ( please refer to the user manual of
iLead controller ). No need to calculate the DMX channels of each fixture in the chain.
·
Automatic switching between DMX function and built-in stand alone programs.
5.3.2 DMX Controller
If you use a universal DMX controller to control the units, you have to set DMX address from
1 to 512 channel so that the units can receive DMX signal.
Press the
MENU
button up to when the
is shown on the display. Pressing
ENTER
button and the display will blink. Use
DOWN
and
UP
button to change the DMX 512 address.
Once the address has been selected, press and keep
ENTER
button pressed up to when
the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change press the
MENU
button again.
Please refer to the following diagram to address your DMX 512 channel for the first 4 units.
16 Channels
:
8 Channels
:
You have to set the fixture DMX address in 8 channels mode when you use IL-0824
controller. DMX address can be set remotely by IL-0824 controller. No need to calculate the
DMX channels of each fixture in the chain.
Please refer to the following diagram to address your DMX 512 channel for the first 4 units.
8 Channels
:
17B
5.4. DMX 512 Configuration
i.) The value as below will be effected after about five seconds,
For DMX reset, put DMX value of CH-16 to 200-209
For DMX lamp on, put DMX value of CH-16 to 130-139.
For DMX lamp off, put DMX value of CH-16 to 230-239.