ACME iSolution Скачать руководство пользователя страница 9

 

16B 

Stand by 

Blackout the unit 

Function 

Strobe 
1. Color sync. strobe 
2. Sync. strobe 
3. Two-light strobe

 

X/Y  moving  show  pattern 
selection 
( Show 1 ~ Show 4 ) 
Please  refer  to  4.2.  Main 
Functions- Show mode 
 

Gobo/Color 
selection  
1.Hold on for gobo 

selection 

2.Press  for  color 

change

 

X/Y moving setting 
1.Pan position 
2.Tilt position 
3.Dimmer  
First set Master unit, then set Slave 
units’ position

 

Mode 

Sound 1 
(LED off ) 

Sound 2 
(LED slow blinking) 

Slow/Sound 3 
(LED on) 

Position/ Latch 
(LED fast blinking) 

 

  5.3.1 iSolution Operation 

 

·

Consistent DMX configuration enable iMove to be linked with iRock and iShow together 

and controlled at the same time. 

·

DMX address can be set remotely by iLead controller ( please refer to the user manual of 

iLead controller ). No need to calculate the DMX channels of each fixture in the chain. 

·

Automatic switching between DMX function and built-in stand alone programs. 

 

  5.3.2 DMX Controller 

 

If you use a universal DMX controller to control the units, you have to set DMX address from 

1 to 512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX 512 address. 

Once the address has been selected, press and keep 

ENTER

 button pressed up to when 

the  display  stops  blinking  or  storing  automatically  8  seconds  later.  To  go  back  to  the 

functions without any change press the

 MENU

 button again.   

Please refer to the following diagram to address your DMX 512 channel for the first 4 units.   

16 Channels

 

 

8 Channels

 

 

You  have  to  set  the  fixture  DMX  address  in  8  channels  mode  when  you  use  IL-0824 

controller. DMX address can be set remotely by IL-0824 controller. No need to calculate the 

DMX channels of each fixture in the chain. 

Please refer to the following diagram to address your DMX 512 channel for the first 4 units. 

 

8 Channels

 

 

 

 

17B 

  5.4. DMX 512 Configuration   

 

 

i.) The value as below will be effected after about five seconds, 

For DMX reset, put DMX value of CH-16 to 200-209 

For DMX lamp on, put DMX value of CH-16 to 130-139. 

For DMX lamp off, put DMX value of CH-16 to 230-239. 

 

Содержание iSolution

Страница 1: ...et The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjust 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 iSolution Operation DMX Controller 5 4 DMX 512 Configuration 5 5 DMX 512 Connection 6 Troubleshooting 7 Fixture Cleaning Широкий ассортимент оборудования ACME на www maxlight ru ...

Страница 2: ...the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts z Don t connect the device to any dimmer pack z Do not touch any wire during operation as high voltage might be causing electric shock Please read carefully the ...

Страница 3: ...Channel 3 Pan Tilt Speed select Channel 11 Prism Channel 4 Dimmer Channel 12 Prism Rotation Channel 5 Shutter Shaking Channel 13 Focus Channel 6 Color Channel 14 Pan 16 bit Channel 7 Iris Channel 15 Tilt 16 bit Channel 8 Gobo 1 Channel 16 Reset Lamp on off 5B 8 Channels Luminous intensity Channel 1 Pan Channel 2 Tilt Channel 3 Shutter Channel 4 Gobo Channel 5 Color Channel 6 Gobo Rotation Iris Cha...

Страница 4: ... age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot In case of replacement of the lamp or maintenance do not open the fixture within 15 minutes until theunit cools down after switching off 7B 4 How To Set The Unit 4 1 Control Panel Display To show the various menus...

Страница 5: ...s To go back to the functions without any change press the MENU button again Show Mode Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the show 1 or show 2 or show 3 or show 4 mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any ...

Страница 6: ...MENU button up to when the is blinking on the display Use the ENTER button to change to the mode display inversion It will automatically store after 8 seconds Or press the ENTER button again return to the mode display normal To go back to the functions press 11B the MENU button Display normal mode for the fixture putting on the floor Display inversion mode for the fixture fixing under ceiling Gobo...

Страница 7: ...an home position Once the position has been selected press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again To go back to the main functions without any change after 8 seconds Tilt offset Press the MENU button for at least 5 seconds into offset mode use DOWN and UP button up to when the is shown on the display Pressing ENTER b...

Страница 8: ...tions without any change press the MENU button again To go back to the main functions without any change after 8 seconds 15B 5 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By IL 0824 only for setting in 8 channel mode please refer to the user guide of iLead controller or by universal DMX controller No need to t...

Страница 9: ...you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds la...

Страница 10: ...annot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by t...

Страница 11: ...the proper address D No response to the sound 1 Make sure the unit that is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition F The lamp is cutting out intermittently 1 The lamp...

Страница 12: ... D and screws E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note it is too tight to rupture 5 Reverse the procedures from point 3 to 2 A B C C E D C F 23B Pay attention to the belt tension when install the belt Please refer to the photos below F G Photo 1 Adjust belt tension through loose the screw Photo 2 ...

Страница 13: ...lean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 ...

Отзывы: