- 44 -
R-Gobo1 Reset Error
Prism1/2 Reset Error
Check whether the position of the prism 1/2 where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the prism 1/2 operating range.
Check whether the Hall element on the prism 1/2 is damaged.
Check whether the lead connecting the Hall element on the prism 1/2
and the PCB board is in poor contact or disconnected.
Check whether the motor on the prism 1/2 is damaged.
Check whether the related circuit of the motor drive board on the
prism 1/2 is damage.
Check whether the position of the gobo wheel 1 where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the gobo wheel 1 operating
range.
Check whether the Hall element on the gobo wheel 1 is damaged.
Check whether the lead connecting the Hall element on the gobo
wheel 1 and the PCB board is in poor contact or disconnected.
Check whether the motor on the gobo wheel 1 is damaged.
Check whether the related circuit of the motor drive board on the
gobo wheel 1 is damage.