ACME FARANDOLE AM-BAR Скачать руководство пользователя страница 13

 
 

182-189 
190-231 
232-239 
240-247 
248-255 

Open 

Fast Open Slow Close 

Open 

Random Strobe 

Open 

000-255 

Dimmer 

 

9 Channels (Mode 2):   

CHANNEL 

VALUE 

FUNCTION 

0-255 

Red 

0-255 

Green 

0-255 

Blue 

0-255 

White 

 

000-007 
008-015 
016-131 
132-139 
140-181 
182-189 
190-231 
232-239 
240-247 
248-255 

Strobe 

Close 
Open 

Strobe Slow->Fast 

Open 

Fast Close Slow Open 

Open 

Fast Open Slow Close 

Open 

Random Strobe 

Open 

000-255 

Dimmer

 

000-255 

Dimmer Fine

 

 

000-007 
008-015 
016-023 
024-030 
031-038 
039-046 
047-054 
055-061 
062-069 
070-077 
078-084 
085-092 
093-100 

Preset Color 

Color 1 
Color 2 
Color 3 
Color 4 
Color 5 
Color 6 
Color 7 
Color 8 
Color 9 

Color 10 
Color 11 
Color 12 
Color 13 

 

12A 

Содержание FARANDOLE AM-BAR

Страница 1: ......

Страница 2: ...ns 3 3 Description 5 3 1 Control Panel 5 4 How To Set The Unit 5 4 1 Main Function 5 4 2 Error Information 9 5 Control By Universal DMX Controller 10 5 1 Connection 10 5 2 Address Setting 11 5 3 DMX 5...

Страница 3: ...he voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperat...

Страница 4: ...n the unit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest a...

Страница 5: ...in out Protection Rating IP20 Features Efficient LED lens uniform color mixing which makes the light effect better 0 100 smooth dimming Adjustable electronic strobe effect Suitable for fixed installat...

Страница 6: ...XLR plug cable to link the units together 4 How To Set The Unit 4 1 Main Function Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is show...

Страница 7: ...ut any change after 1 minute automatically Back to the previous functions without any change press the MENU button Channel Mode Select the press the ENTER button Use the DOWN and UP button to select t...

Страница 8: ...urve 2 Dimmer curve 3 Dimmer curve 4 Optically Linear Square Law Inverse Square Law S Curve Mode 1 Optically Linear The increase in light intensity appears to be linear as DMX value is increased Mode...

Страница 9: ...button Manual Test Select the press the ENTER button Use the DOWN and UP button to select or Once selected press the ENTER button to setup use the DOWN and UP button to adjust the value from 0 to 255...

Страница 10: ...n temperature check board is damaged Memory Initial Fail It appears when the memory IC is damaged CPU B Error CPU C Error CPU D Error They appear when board P C or some wires are damaged Pan Reset Err...

Страница 11: ...The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by th...

Страница 12: ...idle one minute to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 6...

Страница 13: ...39 140 181 182 189 190 231 232 239 240 247 248 255 Strobe Close Open Strobe Slow Fast Open Fast Close Slow Open Open Fast Open Slow Close Open Random Strobe Open 6 000 255 Dimmer 7 000 255 Dimmer Fine...

Страница 14: ...100 139 140 179 180 219 220 255 CTO NO FUNCTION 10000K 7200K 5600K 4200K 3200K 2700K 6 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions fo...

Страница 15: ...tepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 7 Cleaning The cleaning of internal and external optical lenses an...

Страница 16: ...the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN 60598 2 17 19...