background image

 

 

6B 

Channel 5

dip / on: #1, #3 (1+4=5) 

Channel 9

dip / on: #1, #4 (1+8=9) 

Channel 13

dip / on: #1, #3, #4 (1+4+8=13) 

 

 

 

5. DMX 512 Configuration   

 

 

6. DMX 512 Connection   

The DMX 512 is widely used in intelligent lightings and with a maximum of 512 channels. 

 

 

 

7B

 

 
1.  If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin 

adapter-cable. 

2.  At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 

ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin 
XLR-plug and plug it in the DMX-output of the last unit. 

3.  Connect the unit together in a ‘daisy chain’ by XLR plug from the output of the 

unit to the input of the next unit. The cable can not be branched or split to a ‘Y’ 
cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, 
solder joints or corroded connectors can easily distort the signal and shut down 
the system. 

4.  The DMX output and input connectors are pass-through to maintain the DMX 

circuit, when power is connected to the unit. 

5.  Each lighting unit needs to have an address set to receive the data sent by the 

controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 

6.  The end of the DMX 512 system should be terminated to reduce signal errors. 
7.  3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 

 

 

 

7. Fixture Cleaning   

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 

Содержание DAZZLED COLORLED-430

Страница 1: ...DAZZLED COLOR LED 430 User Manual Professional Entertainment Technology 1B ...

Страница 2: ...n a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect mains power before fuse replacement or servicing Replace fuse only with the same type Make sure there are not flammable materials close to the unit while operating as it is fire hazard In the event of serious operating problem stop using the unit immediately Never tr...

Страница 3: ... in master slave mode to perform the great built in pre programmed lighting shows triggered by music In Master Slave mode refer to the DMX settings below Master unit DIP switch 10 ON Slave units All DIP switches OFF 2 light show Turn on the DIP switch 10 for the first unit and DIP switches 1 and 3 for the other then you can enjoy different lighting shows of the two units B Easy Controller by CA 8 ...

Страница 4: ...te or damaged cables solder joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is connected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of...

Страница 5: ...irt on the unit s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 9B ...

Страница 6: ...rovision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements 11B Innovation Quality Performance ...

Отзывы: