background image

 
 

DMX Settings 

To select 

DMX Settings

, press the 

ENTER

 button to confirm, use the 

UP

/

DOWN

 button to select

 

DMX Address

,

 Channel Mode 

or

 View DMX Value. 

DMX Address 

 

To select 

DMX Address

, press the 

ENTER

 button to confirm. Use the 

UP

/

DOWN

 button to 

adjust the address from 

1

 to

 512

, press the 

ENTER

 button to store. Press the 

MENU 

button 

back to the last menu or let the unit idle one minute to exit menu mode. 

Channel Mode   

To select

 Channel

 

Mode

, press the 

ENTER

 button to confirm. Use the 

UP

/

DOWN

 button to 

select 

Mode 1 (4 ch) 

or

 Mode 2 (9 ch) 

mode, press the 

ENTER

 button to store. Press the 

MENU 

button back to the last menu or let the unit idle one minute to exit menu mode. 

View DMX Value 

To select 

View DMX Value

, press the 

ENTER

 button to confirm. Use the 

UP

/

DOWN

 button to 

select 

Red, Green, Blue 

or

 White 

mode,  press  the 

ENTER

  button to store. Press the 

MENU 

button back to the last menu or let the unit idle one minute to exit menu mode. 

Dimmer Curve 

To select 

Dimmer Curve

, press the 

ENTER

 button to show the 

DIMMER CURVE

 on the display, use 

the 

UP/DOWN

 button to select 

Mode 1

,

Mode 2,Mode 3 

or 

Mode 4

. Once selected, press the 

ENTER

 button to store. Press the 

MENU

 button back to the last menu or let the unit idle one 

minute to exit menu mode. 

 

Square Law: 

Light intensity control is finer at low levels and coarser at high levels. 

Inverse Square Law: 

Light intensity control is coarser at low levels and finger at high levels. 

Linear: 

The increase in light intensity appears to be linear as DMX value is increased. 

 

7B 

Содержание CYC-200 FC

Страница 1: ...User Manual Please read the instruc on carefully before use CYC 200 FC...

Страница 2: ...ture 4 3 1 Control Panel 4 3 2 The Plate for Color Filter Barn Door Installation 5 3 3 Main Function 6 4 How To Control The Unit 10 4 1 Master Slave Function 10 4 2 DMX Controller 10 4 3 DMX512 Config...

Страница 3: ...close to the unit while operating as it is fire hazard Use safety cables when fixing this unit Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than thi...

Страница 4: ...he weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed at a place where is out of the reach of people and no one pass by or under it 2 Tech...

Страница 5: ...Panel 4 1 Display Shows the various menus and the selected functions 2 DMX IN For DMX 512 link use 5 pin XLR cable to link the unit to a DMX controller 3 POWER IN Connects to mains supply power 4 POW...

Страница 6: ...ns ENTER To confirm the selected functions 8 Fuse T3 15A To protect the unit from damage of over current 3 2 The Plate for Color Filter Barn Door Installation Please insert the Barn Door into the outs...

Страница 7: ...ink Use the DOWN UP buttons to change the mode Once the required mode has been selected press the ENTER button to confirm To go back to the main functions without any changes press the MENU button aga...

Страница 8: ...xit menu mode View DMX Value To select View DMX Value press the ENTER button to confirm Use the UP DOWN button to select Red Green Blue or White mode press the ENTER button to store Press the MENU but...

Страница 9: ...UP DOWN button to select the No normal display or Yes inverse display press the ENTER button to save Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Backl...

Страница 10: ...Use Time LED Temp or Firmware Version Fixture Use Time To select Fixture Use Time press the ENTER button to confirm and running time of the fixture will show on the display Press the MENU button back...

Страница 11: ...ler to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press the MENU button to enter menu mode select DMX Functions press the ENTER button to conf...

Страница 12: ...WHITE 0 100 5 000 001 006 007 013 014 020 021 027 028 034 035 041 042 048 049 055 056 062 063 069 070 076 077 083 084 090 091 097 098 104 COLOR MACRO Open LEE 790 Moroccan Pink LEE 157 Pink LEE 332 Sp...

Страница 13: ...LEE 088 Lime Green LEE 100 Spring Yellow LEE 104 Deep Amber LEE 179 Chrome Orange LEE 105 Orange LEE 021 Gold Amber LEE 778 Millennium Gold LEE 135 Deep Gold Amber LEE 164 Flame Red 6 000 041 042 083...

Страница 14: ...high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to m...

Страница 15: ...revious one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the c...

Страница 16: ...in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 1BHarmonize...

Отзывы: