background image

 
 

 

2A 

1.

 

Safety

 

Instruction

   

 

WARNING 

 

 

Please

 

keep

 

this

 

User

 

Manual

 

for

 

future

 

consultation.

 

If

 

you

 

sell

 

the

 

unit

 

to

 

another

 

user,

 

be

 

sure

 

that

 

they

 

also

 

receive

 

this

 

instruction

 

booklet.

 

 

Unpack

 

and

 

check

 

carefully

 

there

 

is

 

no

 

transportation

 

damage

 

before

 

using

 

the

 

unit.

 

 

Before

 

operating,

 

ensure

 

that

 

the

 

voltage

 

and

 

frequency

 

of

 

power

 

supply

 

match

 

the

 

power

 

requirements

 

of

 

the

 

unit.

 

 

It’s

 

important

 

to

 

ground

 

the

 

yellow/green

 

conductor

 

to

 

earth

 

in

 

order

 

to

 

avoid

 

electric

 

shock.

 

 

Disconnect

 

mains

 

power

 

before

 

maintenance

 

or

 

servicing.

 

 

Use

 

safety

 

cable

 

when

 

fixes

 

this

 

unit.

 

Don’t

 

handle

 

the

 

fixture

 

by

 

taking

 

its

 

head

 

only,

 

but

 

always

 

taking

 

its

 

base.

 

 

Maximum

 

ambient

 

temperature

 

TA:

 

40 .

 

Don’t

 

operate

 

it

 

when

 

the

 

temperature

 

is

 

higher.

 

 

In

 

the

 

event

 

of

 

serious

 

operating

 

problem,

 

stop

 

using

 

the

 

unit

 

immediately.

 

Never

 

try

 

to

 

repair

 

the

 

unit

 

by

 

yourself.

 

Repair

 

carried

 

out

 

by

 

unskilled

 

people

 

can

 

lead

 

to

 

damage

 

or

 

malfunction.

 

Please

 

contact

 

the

 

nearest

 

authorized

 

technical

 

assistance

 

center

 

and

 

always

 

use

 

the

 

same

 

type

 

spare

 

parts.

 

 

Do

 

not

 

connect

 

the

 

device

 

to

 

any

 

dimmer

 

pack.

 

 

Do

 

not

 

touch

 

any

 

wire

 

during

 

operation

 

as

 

high

 

voltage

 

might

 

be

 

causing

 

electric

 

shock.

 

 

The

 

housing

 

must

 

be

 

replaced

 

if

 

they

 

are

 

visibly

 

damaged.

 

 

Do

 

not

 

look

 

directly

 

at

 

the

 

LED

 

light

 

beam

 

while

 

the

 

fixture

 

is

 

on.

 

 

The

 

unit

 

is

 

for

 

indoor

 

use

 

only

 

and

 

use

 

only

 

in

 

a

 

dry

 

location.

 

 

The

 

unit

 

must

 

be

 

installed

 

in

 

a

 

location

 

with

 

adequate

 

ventilation,

 

at

 

least

 

50cm

 

from

 

adjacent

 

surfaces.

 

Be

 

sure

 

that

 

no

 

ventilation

 

slots

 

are

 

blocked.

 

 

There

 

are

 

no

 

user

 

serviceable

 

parts

 

inside

 

the

 

unit.

 

Do

 

not

 

open

 

the

 

housing

 

or

 

attempt

 

any

 

repairs

 

yourself.

 

In

 

the

 

unlikely

 

event

 

your

 

unit

 

may

 

require

 

service,

 

please

 

contact

 

your

 

nearest

 

dealer.

 

 

 

Please

 

read

 

the

 

instruction

 

carefully

 

which

 

including

 

important

 

information

 

about

 

the

 

installation,

 

operation

 

and

 

maintenance.

 

Содержание COLOR PAR 64

Страница 1: ...COLOR PAR 64 CP 64 BD15 CP 64 PD15 User Manual Please read the instruction carefully before use...

Страница 2: ...switches 5 B Automatic DMX addressing 5 C Remote DMX address setting by CA T DMX TESTER 6 D Remote DMX address setting by Universal DMX controller 6 5 How to control the fixture 7 A Universal DMX con...

Страница 3: ...to repair the unit by yourself Repair carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center and always use the same type...

Страница 4: ...z or AC 230 240 250V 50Hz Power consumption 28 W LED 212pcs Red 70pcs Green 71pcs Blue 71psc Channels Channel 1 Red Channel 2 Green Channel 3 Blue Channel 4 Dimmer Sound Chase Strobe Dimension 216 x 2...

Страница 5: ...between 0 511 usually 0 1 are equal to 1 The address also know as the start channel is the first channel used to receive instructions the controller There are four ways to set the fixture DMX start ad...

Страница 6: ...ure s main PC Board When you hold the button 5secs the fixture will be set the DMX address to 1 and the other fixtures of the chain will be set their own DMX address automatically 2 The fixture used f...

Страница 7: ...ll DMX channels on your DMX controller to zero value 000 5 Set all DMX channels that you want to assign as DMX start address on your projector tot maximum value 255 6 Press the Auto DMX address button...

Страница 8: ...DMX controller The fixture can be set the DMX address remotely by universal DMX controller First you need to programming two scenes into a chase and then link the fixtures to the universal DMX contro...

Страница 9: ...master slave mode There is a terminator for connect the easy controller inside the fixture By connecting the cable into DMX IN waterproof cable gland to the CA 8terminator of the first fixture you wi...

Страница 10: ...utput and input connectors are pass through to maintain the DMX circuit when power is connected to the unit 3 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W re...

Страница 11: ...pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or int...

Страница 12: ...uency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics y Clean with soft cloth using no...

Страница 13: ...e with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008...

Страница 14: ...Innovation Quality Performance...