background image

 

 

 

 

 

 

 

 

COLOR

 

PAR

 

64

 

 

 

CP

64

 

BD15

 

CP

64

 

PD15

 

 

 

                                             

User

 

Manual

 

Please

 

read

 

the

 

instruction

 

carefully

 

before

 

use

 

Содержание COLOR PAR 64

Страница 1: ...COLOR PAR 64 CP 64 BD15 CP 64 PD15 User Manual Please read the instruction carefully before use...

Страница 2: ...switches 5 B Automatic DMX addressing 5 C Remote DMX address setting by CA T DMX TESTER 6 D Remote DMX address setting by Universal DMX controller 6 5 How to control the fixture 7 A Universal DMX con...

Страница 3: ...to repair the unit by yourself Repair carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center and always use the same type...

Страница 4: ...z or AC 230 240 250V 50Hz Power consumption 28 W LED 212pcs Red 70pcs Green 71pcs Blue 71psc Channels Channel 1 Red Channel 2 Green Channel 3 Blue Channel 4 Dimmer Sound Chase Strobe Dimension 216 x 2...

Страница 5: ...between 0 511 usually 0 1 are equal to 1 The address also know as the start channel is the first channel used to receive instructions the controller There are four ways to set the fixture DMX start ad...

Страница 6: ...ure s main PC Board When you hold the button 5secs the fixture will be set the DMX address to 1 and the other fixtures of the chain will be set their own DMX address automatically 2 The fixture used f...

Страница 7: ...ll DMX channels on your DMX controller to zero value 000 5 Set all DMX channels that you want to assign as DMX start address on your projector tot maximum value 255 6 Press the Auto DMX address button...

Страница 8: ...DMX controller The fixture can be set the DMX address remotely by universal DMX controller First you need to programming two scenes into a chase and then link the fixtures to the universal DMX contro...

Страница 9: ...master slave mode There is a terminator for connect the easy controller inside the fixture By connecting the cable into DMX IN waterproof cable gland to the CA 8terminator of the first fixture you wi...

Страница 10: ...utput and input connectors are pass through to maintain the DMX circuit when power is connected to the unit 3 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W re...

Страница 11: ...pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or int...

Страница 12: ...uency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics y Clean with soft cloth using no...

Страница 13: ...e with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008...

Страница 14: ...Innovation Quality Performance...

Отзывы: