ACME CM-70Z Скачать руководство пользователя страница 3

 
                                                                                     

 

2A

 

1.

 

Safety

 

Instructions

   

 

 

WARNING

 

Please

 

keep

 

this

 

User

 

Guide

 

for

 

future

 

consultation.

 

If

 

you

 

sell

 

the

 

unit

 

to

 

another

 

user,

 

be

 

sure

 

that

 

they

 

also

 

receive

 

this

 

instruction

 

booklet.

 

y

 

Please

 

unpack

 

and

 

check

 

carefully

 

there

 

is

 

no

 

transportation

 

damage

 

before

 

using

 

the

 

unit.

 

y

 

Before

 

operating,

 

ensure

 

that

 

the

 

voltage

 

and

 

frequency

 

of

 

power

 

supply

 

match

 

the

 

power

 

requirements

 

of

 

the

 

unit.

   

y

 

It’s

 

important

 

to

 

ground

 

the

 

yellow/green

 

conductor

 

to

 

earth

 

in

 

order

 

to

 

avoid

 

electric

 

shock.

 

y

 

The

 

unit

 

is

 

for

 

indoor

 

use

 

only.

 

Use

 

only

 

in

 

a

 

dry

 

location.

 

y

 

The

 

unit

 

must

 

be

 

installed

 

in

 

a

 

location

 

with

 

adequate

 

ventilation,

 

at

 

least

 

50cm

 

from

 

adjacent

 

surfaces.

 

Be

 

sure

 

that

 

no

 

ventilation

 

slots

 

are

 

blocked.

   

y

 

Please

 

disconnect

 

main

 

power

 

before

 

replacement

 

or

 

servicing.

   

y

 

Please

 

make

 

sure

 

there

 

are

 

no

 

flammable

 

materials

 

close

 

to

 

the

 

unit

 

while

 

operating

 

as

 

it

 

is

 

fire

 

hazard.

   

y

 

Please

 

use

 

safety

 

cable

 

when

 

fixes

 

this

 

unit.

 

DO

 

NOT

 

handle

 

the

 

unit

 

by

 

taking

 

its

 

head

 

only,

 

but

 

always

 

by

 

taking

 

its

 

base.

     

y

 

Maximum

 

ambient

 

temperature

 

is

 

Ta:

 

40

.

 

DO

 

NOT

 

operate

 

it

 

where

 

the

 

temperature

 

is

 

higher

 

than

 

this.

 

y

 

Unit

 

surface

 

temperature

 

may

 

reach

 

up

 

to

 

75

.

 

DO

 

NOT

 

touch

 

the

 

housing

 

bare

hand

 

during

 

its

 

operation.

 

Turn

 

off

 

the

 

power

 

and

 

allow

 

about

 

15

 

minutes

 

for

 

the

 

unit

 

to

 

cool

 

down

 

before

 

replacing

 

or

 

serving.

 

y

 

In

 

the

 

event

 

of

 

serious

 

operating

 

problem,

 

stop

 

using

 

the

 

unit

 

immediately.

 

Never

 

try

 

to

 

repair

 

the

 

unit

 

by

 

yourself.

 

Repairs

 

carried

 

out

 

by

 

unskilled

 

people

 

can

 

lead

 

to

 

damage

 

or

 

malfunction.

 

Please

 

contact

 

the

 

nearest

 

authorized

 

technical

 

assistance

 

center.

 

Always

 

use

 

the

 

same

 

type

 

spare

 

parts.

 

y

 

DO

 

NOT

 

touch

 

any

 

cables

 

during

 

operation

 

as

 

high

 

voltage

 

might

 

be

 

causing

 

electric

 

shock.

 

 

Please

 

read

 

the

 

instruction

 

carefully

 

which

 

includes

 

important

 

information

 

about

 

the

 

installation,

 

usage

 

and

 

maintenance.

 

Содержание CM-70Z

Страница 1: ...CM 70Z User Manual Please read the instruction carefully before use ...

Страница 2: ...The Unit 4 3 1 Control Panel 4 3 2 Main Function 5 3 3 Home Position Adjustment 11 4 How to Control the Unit 12 4 1 Master Slave Built In Preprogrammed Function 12 4 2 DMX Controller 12 4 3 DMX 512 Configuration 13 5 DMX512 Connection 15 6 Troubleshooting 16 7 Fixture Cleaning 17 ...

Страница 3: ...le materials close to the unit while operating as it is fire hazard y Please use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base y Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this y Unit surface temperature may reach up to 75 DO NOT touch the housing bare hand during its operation Turn of...

Страница 4: ...hat the unit is firmly fixed to avoid vibration and slipping while operating Make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed in a pl...

Страница 5: ...Cable Daisy Chains 8 Fixtures Max 230V 50Hz 4 Fixtures Max 120V 60Hz Light Source 7 x 10W OSRAM OSTAR RGBW LED Beam angle 10 60 Weight 6 2Kgs Dimension 267 x 163 x 321mm 3 How To Set The Unit 3 1 Control Panel 1 Function Display To show the various menus and the selected functions ...

Страница 6: ... the optional CA 8 to control the unit 8 DMX OUT DMX512 link use 3 pin XLR cable to link the next unit and output DMX signal 9 DMX IN DMX512 link use 3 pin XLR cable to link the unit and the DMX controller 3 2 Main Function To select any of the given functions press the MENU button up to the required selection as shown on the display Select the function by the ENTER button and the display will bli...

Страница 7: ...6A ...

Страница 8: ...in Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Slave Mode To select Slave Mode press the ENTER button to show the SLAVE MODE on the display Use the DOWN UP button to select the Slave 1 or Slave 2 mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press a...

Страница 9: ...lected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Sound Sense To select Sound Sense press the ENTER button to show the SOUND SENSE on the display Use the DOWN UP button to adjust the sensitivity level the sensitivity level can be adjusted ...

Страница 10: ...U button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Tilt Inverse To select Tilt Inverse press the ENTER button to show the TILT INVERSE on the display Use the DOWN UP button to select the Yes tilt inversion or No normal mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change pres...

Страница 11: ...etup go back to the functions without any change press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Auto Test To select Auto Test press the ENTER button and the unit will run self test by built in program To go back to the functions press the MENU button again Press and hold the MENU button about one second or wait for one m...

Страница 12: ... hold the MENU button for about one second or wait for one minute to exit the menu mode Reset To select Reset press the ENTER button to show the RESET on the display and all channels of the unit will return to their standard position Press and hold the MENU button for about one second or wait for one minute to exit the menu mode 3 3 Home Position Adjustment In the main functions hold the ENTER but...

Страница 13: ...ack will have nothing plugged into it and its master LED will be constantly on and sound LED will flash to the music The other units will have to set in slave mode and select Slave 1 normal or Slave 2 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave led lights will constantly on 2 light show In slave mode Slave 1 means the unit works normally and Slave ...

Страница 14: ...00 255 TILT FINE 5 000 255 PAN TILT SPEED fast slow 6 000 009 010 014 015 255 SPECIAL FUNCTIONS No function Reset No function 7 000 255 DIMMER 0 100 8 000 019 020 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 SHUTTER Closed Open Strobe 1 fast slow Open Strobe 2 opening pulse fast slow Open Strobe 3 closing pulse fast slow Open S...

Страница 15: ...4 145 149 150 154 155 159 160 164 COLOR MACRO Open LEE 790 Moroccan Pink LEE 157 Pink LEE 332 Special Rose Pink LEE 328 Follies Pink LEE 345 Fuchsia Pink LEE 194 Surprise Pink LEE 181 Congo Blue LEE 071 Tokyo Blue LEE 120 Deep Blue LEE 079 Just Blue LEE 132 Medium Blue LEE 200 Double CT Blue LEE 161 State Blue LEE 201 Full CT Blue LEE 202 Half CT Blue LEE 117 Steel Blue LEE 353 Lighter Blue LEE 11...

Страница 16: ...4 Flame Red Open Color wheel rotation effect Clockwise fast slow Stop this will stop wherever the color is at the time Counter clockwise slow fast Open Random color Fast Medium Slow Open 14 000 255 ZOOM wide narrow 5 DMX512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels ...

Страница 17: ...ds to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX 512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 Pi...

Страница 18: ... unit does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone 3 Make sure the fixture is not set into Blackout mode E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 7 Fixture Cleaning The cleaning must be carried out periodicall...

Страница 19: ...h the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Страница 20: ...Innovation Quality Performance ...

Отзывы: