Backlight Intensity 

To select 

Backlight Intensity

, press the 

ENTER

 button to show the 

BACKLIGHT INTENSITY

 on 

the display. Use the 

UP/DOWN

 button to adjust the intensity from 

(dark) to 

10 

(bright). Once 

selected, press the 

ENTER

 button to setup and store. Press the 

MENU

 button back to the last 

menu or let the unit idle one minute to exit menu mode. 

Temperature Unit 

To Select 

Temperature Unit

, press the 

ENTER

 button to show the 

TEMPERATURE UNIT

 on the 

display. Use the 

UP/DOWN

 button to select 

 or 

̧

, press the 

ENTER

 button to store. Press the 

MENU

 button back to the last menu or let the unit idle one minute to exit menu mode.

 

Display Warning 

To select 

Display Warning

, press the 

ENTER

 button to show the 

DISPLAY WARNING

 on the 

display. Use the 

UP/DOWN

 button to select 

No 

(Normal) or 

Yes

 (display will show the error 

warning when the unit went wrong), press the 

ENTER

 button to store. Press the 

MENU

 button 

back to the last menu or let the unit idle one minute to exit menu mode. 

Fixture Test 

Enter 

MENU

 mode, select 

Fixture Test

, press the 

ENTER

 button to confirm, use the 

UP/DOWN 

button to select

 Auto Test 

or

 Manual Test

 

Auto Test 

To select 

Auto Test

, press the 

ENTER

 button to show the 

AUTO TEST

 on the display. Press the 

ENTER

 button, the unit will run built-in programs to automatically test pan, tilt and zoom. Press 

the 

MENU

 button back to the last menu or exit menu mode after auto test. 

Manual Test 

To select 

Manual Test

, press the 

ENTER

 button to show the 

MANUAL TEST 

on the display. 

Press the 

ENTER

 button, and then use the 

UP/DOWN

 button to select channel, and adjust the 

channel value. Once selected, press the 

ENTER

 button to setup, the fixture will run as the channel 

value indicates. Press the 

MENU

 button back to the last menu or exit menu mode let the unit idle 

one minute.   

(All channels value will become 0 after exiting 

Manual Test 

menu) 

 

10A 

Содержание CM-350Z

Страница 1: ...CM 600Z User Manual Please read the instruction carefully before use...

Страница 2: ...ns 3 3 How To Set The Unit 4 3 1 Control panel 4 3 2 Main Function 5 3 3 Home Position Adjustment 13 4 Control By Universal DMX Controller 13 4 1 DMX 512 Connection 13 4 2 Address Setting 14 4 3 DMX 5...

Страница 3: ...ose to the unit while operating as it is fire hazard y Use safety cables when fixing this unit DO NOT handle the unit by its head only always carry by its base y Maximum ambient temperature is Ta 40 d...

Страница 4: ...ping while operating and make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight Always use a safety cable that ca...

Страница 5: ...Fixture Max 120V 60Hz LED Source 37 10W OSRAM OSTAR LED Beam Angel 10 60 Weight 19 5Kgs Dimension 430 246 512mm 3 How To Set The Unit 3 1 Control panel 1 Function Display Shows the various menus and...

Страница 6: ...connection for main power supply to the next unit 8 Fuse T 10A Protects the unit from over voltage or short circuit 3 2 Main Function To select any of the given functions press the MENU button until...

Страница 7: ...6A...

Страница 8: ...tton to show the VIEW DMX VALUE on the display Use the UP DOWN button to view the DMX channel values Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixtu...

Страница 9: ...the ENTER button to show the WHITE BALANCE on the display use the UP DOWN button to select Red Green or Blue Once selected press the ENTER button to confirm and use the UP DOWN button to adjust the v...

Страница 10: ...e select Display Setting press the ENTER button to confirm use the UP DOWN button to select Display Inverse Backlight Auto Off Backlight Intensity Temperature unit or Display Warning Display Inverse T...

Страница 11: ...en the unit went wrong press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Test Enter MENU mode select Fixture Test pr...

Страница 12: ...rmware Version To select Firmware Version press the ENTER button to show the FIRMWARE VERSION on the display Press the ENTER button and the fixture software version will show on the display Press the...

Страница 13: ...TURE MAINTENANCE on the display Use the UP DOWN button to select Interval or Remain Time Interval To select Interval press the ENTER button to confirm the interval time will be shown on the display Pr...

Страница 14: ...TER button to confirm Use the DOWN UP button to adjust the home position of the Pan Tilt or Zoom Once the position has been selected press the ENTER button to setup to go back to the functions without...

Страница 15: ...et to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX 512 system should be terminated to reduce signal errors 7 3 pin XLR co...

Страница 16: ...ase refer to the following diagram to set the DMX address for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 14 channels 1 15 29 43 26 channels 1 27 53 79 1...

Страница 17: ...5 129 130 144 145 149 150 164 165 169 170 184 185 189 190 204 205 209 210 224 225 229 230 244 245 255 SHUTTER Blackout Open Strobe 1 fast slow Open Strobe 2 opening pulse fast slow Open Strobe 3 closi...

Страница 18: ...k LEE 181 Congo Blue LEE 071 Tokyo Blue LEE 120 Deep Blue LEE 079 Just Blue LEE 132 Medium Blue LEE 200 Double CT Blue LEE 161 State Blue LEE 201 Full CT Blue LEE 202 Half CT Blue LEE 117 Steel Blue L...

Страница 19: ...L FUNCTIONS No function Reset No function 8 000 255 DIMMER 0 100 9 000 019 020 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 SHUTT...

Страница 20: ...025 032 033 039 040 047 048 054 055 061 062 069 070 076 077 084 085 091 092 099 100 106 107 113 114 121 122 128 129 136 137 143 144 151 152 158 159 165 166 173 174 180 181 188 189 195 196 203 204 210...

Страница 21: ...00 22 000 255 RING 3 BLUE 0 100 23 000 255 RING 3 WHITE 0 100 24 000 255 RING 3 COLOR PRESET The same as CH14 RING 1 COLOR PRESET 25 000 007 008 022 023 037 038 052 053 067 068 082 083 097 098 112 113...

Страница 22: ...r on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX int...

Страница 23: ...with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 Al...

Страница 24: ...Innovation Quality Performance 23A...