ACME BP-40 QW S DXX Скачать руководство пользователя страница 11

13B 

4. How To Control The Unit   

You can operate the unit by DMX controller: 

No  need  to  turn  the  unit  off  when  you  change  the  DMX  address,  as  new  DMX 

address setting will be affected at once. Every time you turn the unit on, it will show 

  on the display. After that the unit will be ready to receive DMX signal or 

run the built in programs. 

4.1 DMX Controller   

Use universal DMX controller to control the units, you have to set DMX address from 

1 to 512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display.   

Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to 

change the DMX512 address. Once the address has been selected, press and keep 

ENTER

 button pressed up to when the display stops blinking or storing 

automatically 8 seconds later. To go back to the functions without any change press 

the

 MENU

 button again.   

Please refer to the following diagram to address your DMX512 channel for the first 

4 units

 

 

 

 

10B 

UP

  button  to  select  the 

  (red), 

  (green), 

  (blue), 

 

(yellow), 

  (purple), 

  (Cyan), 

  (white)  or 

  (fade). 

Once select 

, press the 

ENTER

 button  to setup. press the 

ENTER 

button

  will blinking on the display, use 

DOWN

 and 

UP

 button adjust the fade time 

(0~255), press the 

ENTER 

button to store and 

  will blinking on the display, 

use the 

DOWN

 and 

UP 

button adjust the white time (0~255), press the 

ENTER

 button 

to store or automatically return to the main functions without any change after one 

minute. To go back to the previous functions without any change press the 

MENU

 

button. 

 

 

White Balance

 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

the

 ENTER

 button and the display will blink. Use the

 DOWN

 and 

UP

 button to select 

the 

  (red), 

  (green), 

  (blue)  mode.  Once  selected,  press 

the

 ENTER

 button to setup, then use the

 DOWN

 and 

UP

 button to adjust the value 

(125~255) or automatically exit menu mode without any change after one minute. 

To go back to the functions without any change press the 

MENU

 button. 

 

  Photo Cell Mode

 

Select the 

, press the

 ENTER

 button and the display will blink. Use the

 DOWN

 and 

UP

 

button  to  select  the 

 

(Be  controlled  by  sunlight)  or 

 

(Not  be  controlled  by 

sunlight)

Once  select,  press  the 

ENTER 

button  to  setup  or  automatically  return  to  the  main 

functions  without  any  change  after  one  minute.  Back  to  the  previous  functions  press  the

  MENU

 

button. 

Содержание BP-40 QW S DXX

Страница 1: ...Innovation Quality Performance BUILDING PROJECTOR BP 40 QW S DXX User Manual Please read the instructions carefully before use...

Страница 2: ...1B CONTENT 1 Safety Instructions 2 2 Technical Specifications 3 3 How To Set The Fixture 5 4 How To Control The Unit 13 5 DMX512 Connections 15 6 Troubleshooting 17 7 Cleaning And Maintenance 18...

Страница 3: ...age before using the fixture Please install and operate by qualified technician Before operating ensure that the voltage and frequency of power supply match the power requirements of the fixture It s...

Страница 4: ...ixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Please disconnect the mains power if the...

Страница 5: ...0598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements 4B environment is getting dark A nice design to put diffusion filte...

Страница 6: ...ions ENTER To confirm the selected functions 18B 7 Cleaning And Maintenance The cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in whic...

Страница 7: ...k of the last unit of the connection It has been set up an operating mode different from the DMX mode used Check the operating mode set up Try to use another DMX controller 6B 3 DMX IN Water proof 3 p...

Страница 8: ...units power is disconnected 4 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 The end of the...

Страница 9: ...without any change after one minute Back to the previous functions without any change press the MENU button Channel Mode Select the press the ENTER button and the display will blink Use the DOWN and U...

Страница 10: ...Manual Mode Press the MENU button up to when the is shown on the display Press the ENTER button and the display will blink Use the DOWN and UP button to select the set the color or store the color On...

Страница 11: ...Once select press the ENTER button to setup press the ENTER button will blinking on the display use DOWN and UP button adjust the fade time 0 255 press the ENTER button to store and will blinking on t...

Страница 12: ...n functions without any change after one minute To go back to the previous functions without any change press the MENU button Auto Test Select the press the ENTER button and the unit will run the buil...

Отзывы: