background image

 

8B 

  (normal).

 

Once  selected,  press  the 

ENTER

  button  to store.  To  return  to  the  main 

menu without any changes press the

 MENU

 button. Hold and press the 

MENU

 button about 

one second or wait for one minute to exit the menu mode. 

  LED display 

Press the 

MENU

 button to show 

  on the display. Press the 

ENTER

 button and the 

display  will  blink.  Use  the 

DOWN

  and 

UP

  buttons  to  select  the 

  (display  on)  or 

(display off) mode. Once selected, press the 

ENTER

 button to store. To return to the 

main menu without any changes press the

 MENU

 button. Hold and press the 

MENU

 button 

about one second or wait for one minute to exit the menu mode. 

  Display Inverse 

Press the 

MENU

 button to show 

  on the display. Press the 

ENTER

 button and the 

display will blink. Use the 

DOWN

 and 

UP

 buttons to select the 

  (normal) or 

 

(inverse),  Once  selected,  press  the 

ENTER

  button  to  store.  To  return  to  the  main  menu 

without any changes press the

 MENU

 button. Hold and press the 

MENU

 button about one 

second or wait for one minute to exit the menu mode. 

  Self-Test 

Press the 

MENU

 button to show 

  on the display. Press 

ENTER

 button and the unit 

will  run  the  built-in  programmer  for self-test.  To  return  to  the  main menu  press  the

 MENU

 

button. Hold and press the 

MENU

 button about one second or wait for one minute to exit the 

menu mode. 

    Fixture Hours

 

Press the 

MENU

 button to show 

  on the display. Press the 

ENTER

 button and the 

display will show the number of working hours of the unit. To return to the main menu press 

the

  MENU

  button.  Hold  and  press  the 

MENU

  button  about  one  second  or  wait  for  one 

minute to exit the menu mode. 

 

Software version

 

Press the 

MENU

 button to show 

  on the display. Press the

 ENTER

 button and the 

display will show the version of software  inside the unit. To return to the main menu press 

the

  MENU

  button.  Hold  and  press  the 

MENU

  button  about  one  second  or  wait  for  one 

minute to exit the menu mode. 

Содержание BARRAGE LED-247

Страница 1: ...BARRAGE LED 247 User Manual Please read the instructions carefully before use ...

Страница 2: ...1B ...

Страница 3: ... TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How to Set the Fixture 4 How to Control the Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning ...

Страница 4: ...thorized technical assistance center Always use the same type spare parts Do not connect the unit to any dimmer pack Do not touch any wire during operation and there may be a hazard of electric shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The housing must be replaced if they are visibly damaged Do not look directly at the LED light b...

Страница 5: ...cs Blue 2pcs White 2pcs Dimension 510 x 120 x 150 8 mm Weight 4 3kgs 3 How to Set the Fixture 3 1 Rear panel 1 Hanging bracket With 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting hook 2 Rotating optical barrel Don t touch while in use 3 DISPLAY Shows the various menus and the selected functions ...

Страница 6: ...cable to link the next unit 12 Mains output Connect to supply power for the next unit 13 Mains input Connect to power supply 3 2Main Function To select any of the given functions press the MENU button to show the required option on the display Select the function with the ENTER button and the display will blink Use the DOWN and UP buttons to change the mode Once the required mode has been selected...

Страница 7: ... MENU button to show on the display Press the ENTER button and the display will blink Use the DOWN and UP buttons to change the DMX address Once the address has been selected press the ENTER button to store To return to the main menu ...

Страница 8: ...Hold and press the MENU button about one second or wait for one minute to exit the menu mode Sound Mode Press the MENU button to show on the display Press the ENTER button and the display will blink Use the DOWN and UP buttons to select the sound on or sound off Once selected press the ENTER button to store To return to the main menu without any changes press the MENU button Hold and press the MEN...

Страница 9: ...e To return to the main menu without any changes press the MENU button Hold and press the MENU button about one second or wait for one minute to exit the menu mode Self Test Press the MENU button to show on the display Press ENTER button and the unit will run the built in programmer for self test To return to the main menu press the MENU button Hold and press the MENU button about one second or wa...

Страница 10: ... light show This function is good when you want an instant show You have to set the first unit in master mode and select auto show show 1 or or show 8 Its DMX input jack will have nothing plugged into it and Its master LED will be constantly on and sound LED will flash to the music The slave units will have to select normal or 2 light show mode Their DMX cables plugged into the DMX input jacks dai...

Страница 11: ...uttons to change the DMX address Once the address has been selected press the ENTER button to store To return to the main menu without any changes press the MENU button or wait for one minute Please refer to the following diagram to address your DMX channels for the first 4 units 5channels 5 DMX512 Configuration Blackout Blackout the unit Function 1 Synchronous Strobe in full ON 2 Sound Strobe in ...

Страница 12: ... one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 51...

Страница 13: ...xtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture is not receiving a DMX signal 2 Check microphone to see if it is good by tapping the microphone 8 Fixture Cleaning The cleaning of internal mu...

Страница 14: ...13B ...

Страница 15: ...rdance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements ...

Страница 16: ...15B Innovation Quality Performance ...