or disconnected.
4. Tilt Reset Error
Check whether the position of the tilt where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the tilt operating range.
Check whether the Hall element on the tilt is damaged.
Check whether the lead connecting the Hall element on the tilt and the PCB board is in poor
contact or disconnected.
Check whether the motor on the tilt is damaged.
Check whether the related circuit of the motor drive board on the tilt is damage.
5. Tilt Encode Error
Check whether the encoder on the tilt is damaged.
Check whether the lead connecting the encoder on the tilt and the PCB board is in poor contact or
disconnected.
6. Cyan Reset Error
Check whether the position of the cyan color wheel where the magnet is installed falls off or is
damaged.
Check whether there are obstacles in the cyan color wheel operating range.
Check whether the Hall element on the cyan color wheel is damaged.
Check whether the lead connecting the Hall element on the cyan color wheel and the PCB board is
in poor contact or disconnected.
Check whether the motor on the cyan color wheel is damaged.
Check whether the related circuit of the motor drive board on the cyan color wheel is damage.
7. Magenta Reset Error
Check whether the position of the magenta color wheel where the magnet is installed falls off or is
damaged.
Check whether there are obstacles in the magenta color wheel operating range.
Check whether the Hall element on the magenta color wheel is damaged.
Check whether the lead connecting the Hall element on the magenta color wheel and the PCB
board is in poor contact or disconnected.
Check whether the motor on the magenta color wheel is damaged.
Check whether the related circuit of the motor drive board on the magenta color wheel is damage.