Do not operate in dirty or dusty environment; do clean the fixture regularly. 

 

Do not touch any wire during operation as there might be a hazard of electric shock. 

 

Avoid power wires twist other cables. 

 

The minimum distance between light output and the illuminated surface must be more than 

12 meters. 

 

Disconnect mains power before fuse/lamp replacement or servicing. 

 

Replace fuse/lamp only with the same type. 

 

In the event of serious operating problem, stop using the unit immediately.   

 

Never turn on and off the unit time after time. 

 

The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. 

 

Do not open the unit as there are no user serviceable parts inside. 

 

Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to 

damage or malfunction. Please contact the nearest authorized technical assistance center if 

needed. 

 

Disconnect the mains power if the fixture is has not been used for a long time. 

 

Do use the original packing materials before transporting it once again. 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

 

Hot lamp explosion hazard. Do not open the unit within 15 minutes after switching off. 

 

Do replace the bulb once it is damaged, deformed or life-expired. 

 

Do not look directly at the light while the bulb is on. 

 

Never touch bulb with bare fingers, as it is very hot after using. 

 

Do not start on the unit without bulb enclosure or when housing is damaged. 

3A 

 

Содержание AE-610 BEAM

Страница 1: ...AE 610 BEAM User Manual Please read the instruction carefully before use...

Страница 2: ...3 1 Control Panel 5 4 How To Set The Unit 5 4 1 Main Function 5 4 2 Home Position Adjustment 10 4 3 Error Information 11 5 Control By Universal DMX Controller 12 5 1 Connection 12 5 2 Address Setting...

Страница 3: ...f power supply matches the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 Don t operate...

Страница 4: ...t as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized...

Страница 5: ...Master slave Sound active LCD display easy to control One gobo wheel One color wheel Smooth 0 100 dimming and variable strobe speeds Voltage AC 100 240V 50 60Hz Power Consumption 190W LED OSRAM SIRIUS...

Страница 6: ...ly power 7 DMX In out Water proof cable with 3 pin XLR connectors for DMX 512 operation 4 How To Set The Unit 4 1 Main Function Turn on the unit press the MENU button into menu mode press the UP and D...

Страница 7: ...6A...

Страница 8: ...ct the Slave 1 normal or Slave 2 2 light show mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press and...

Страница 9: ...t Inverse press the ENTER button to show the TILT INVERSE on the display Use the DOWN UP button to select the Inverse tilt inversion or Normal normal mode Once the mode has been selected press the ENT...

Страница 10: ...amp Power On To select Lamp Power On press the ENTER button to show the LAMP POWER ON on the display Use the DOWN UP button to select the On Lamp on when power on or Off Lamp off when power off Once s...

Страница 11: ...show the PAN OFFSET on the display Use the DOWN and UP button to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit TILT OFFSET Tilt home position adjustmen...

Страница 12: ...djust the value from 0 to 255 press the ENTER button to store Press the MENU button to exit 4 3 Error Information Lamp Startup Fail It appears when there is no lamp or some wires are damaged Temperatu...

Страница 13: ...e qualified maintenance 5 Control By Universal DMX Controller 5 1 Connection 1 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pi...

Страница 14: ...se a universal DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press EN...

Страница 15: ...robe Open 8 000 008 009 016 017 025 026 033 034 042 043 050 051 059 060 067 068 076 077 084 085 093 094 101 102 110 111 118 119 127 128 189 190 193 194 255 COLOR Open Color1 Color2 Color3 Color4 Color...

Страница 16: ...ing Gobo13 Shaking Gobo14 Shaking Gobo15 Shaking Rotation Fast Slow Stop Rotation Slow Fast 10 000 007 008 255 PRISM No Effect Prism Effect 11 000 127 128 189 190 193 194 255 R PRISM Index 0 360 Rotat...

Страница 17: ...hannel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX contro...

Страница 18: ...would cause malfunction of the fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depend...

Страница 19: ...cordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN...

Страница 20: ...Innovation Quality Performance 19A...

Отзывы: