4. GETTING
STARTED
Before applying power to the module, select the MIDI controller number to be mapped to
the CC output by setting the DIP switches on the back of the Mini MIDI (see table 1). Most
commonly used MIDI Control Change Numbers are implemented.
The default Control Change number, i. e. when all DIP switches are in off position, is CC 1
“Modulation Wheel”. The DIP switches will be read once at power up time.
The PITCH and GATE outputs can be connected to Pitch and Gate signals on the
Eurorack power connector using the Pitch and Gate jumpers at the back of the Mini
MIDI.
1
2
3
4 MIDI Controller
0
0
0
0 Modulation Wheel
1
0
0
0 Breathe Control
0
1
0
0 Foot Control
1
1
0
0 Channel volume
0
0
1
0 Balance
1
0
1
0 Pan
0
1
1
0 Expression
1
1
1
0 Effects controller 1
0
0
0
1 Effects controller 2
1
0
0
1 General purpose 1
0
1
0
1 General purpose 2
1
1
0
1 General purpose 3
0
0
1
1 General purpose 4
1
0
1
1
Channel Pressure
(Aftertouch)
0
1
1
1
Note On Velocity
1
1
1
1
Calibration Mode
Table 1: DIP switches settings. 0 = off, 1 = on
The three last rows of 1 contain
special modes:
•
Channel´s Pressure:
In this mode the value of incoming “Channel Pressure”
(aftertouch) messages will be mapped to the CC output rather than the values of
incoming Control Change messages.
•
Note On Velocity:
In this mode the note velocity of incoming “Note On” messages
will be mapped to the CC output rather than the values of incoming Control Change
messages.
8