background image

Calibration

Each unit is individually calibrated during testing.

Battery life (while connected)

Unlimited - mains powered and battery back up.

Battery life (while unconnected to mains)

The 9V Alkaline batteries should last for at least 9,000 hours 

(1 year).

Caution

The battery used in this device may present a risk of fire or 

chemical burn if mistreated. Do not recharge, disassemble, heat 

above 100°C or incinerate. Replace with a 9V Lithium or Alkaline 

battery IEC Type 6-F22 (PP3, MN1604). Use of another battery 

may present a risk of fire or explosion. Dispose of used batteries 

promptly. Check for signs of battery (electrolyte) leakage. If 

leakage has occurred, the PCB must be cleaned in an approved 

manner by a competent (trained) person. Keep away from 

children.

Electrocorder Model: EC-2VA

3 of 3

Maintenance

Regularly check the Electrocorder casing for signs of damage 

(cracks, broken or loose parts) or misuse. If the unit is damaged 

in any way it must  NOT be used and should be returned to the 

supplier. The unit must not  be used for any other purpose than 

for that recommended by the manufacturer. The unit must not be 

submerged in any liquid. 

Cleaning

Wipe the outside of the case with a clean cloth damped with IPA 

(Isopropyl Alcohol).

Warranty

All Acksen products carry a minimum 1 year’s warranty covering 

manufacturing defects and component failures. The device 

contains no user-serviceable parts and as such should only be 

repaired by skilled and authorised personnel. Failure to comply 

could result in unsafe operation and should not be attempted 

under any circumstances. Contact below for a list of approved 

service agents. Note: Any unauthorised repair or adjustment will 

automatically render the warranty invalid.

Repair and spare parts

Acksen Ltd, 28 Station  Road, Whiteabbey

Newtownabbey, Co. Antrim BT37 0AW United Kingdom

Or an approved repair company.

Returning a product for repair

If returning a product to the manufacturer for repair, it should be 

sent freight pre-paid to the appropriate address. A copy of the 

Invoice and of the packing note should be sent simultaneously by 

airmail to expedite clearance through Customs. A repair estimate 

showing freight return and other charges will be submitted to the 

sender, if required, before work on the device commences. 

WEEE

For EU customers Acksen Ltd offer a product take-back service. 

For customers within the European Union (only) and products 

manufactured or sold by us; when those products reach the end 

of their life, simply send them back to us at your expense, we will 

dispose of them according to the relevant legislation. WEEE Reg. 

No. WEE/DD2117VU

Measurement range (Vrms) 

0Vac 300Vrms (Ph – N) 

Maximum channel input voltage 

300Vrms (Ph – N)

Voltage measurement accuracy 

±1.5% of reading (10 bit) within 70Vac –  

 

 

300Vrms (Ph – N); else ±3%. (50/60Hz ±2%) 

Current range 

0 – 300A (other ranges can be factory set) 

Current measurement accuracy 

3% of reading 50 to 300A, otherwise 5% 

Dimensions of current sensor 

Max conductor diameter 120mm (5”) 

Vmin & Vmax meas time resolution 

Always one cycle (50/60 Hz), independent of 

 

selected averaging period 

Sampling frequency 

16 samples per cycle 800Hz @ 50Hz or 960Hz  

 

@ 60Hz 

Data recorded 

Average voltage/current, max & min voltage/ 

 

currentcycle-value during the averaging  

 

 period 
Memory capacity 

128kB able to record 32,000 Voltage levels per 

 channel 
Memory type 

Non-volatile SEEPROM 

Memory - averaging period & duration 

1 sec to 60 mins (1sec. avg gives 2 hrs of log   

 

ging, 60min. avg gives 300 days of logging) 

Real-time clock accuracy 

Greater than 0.001% 

Input lead length 

Metric 1.0 metres    Imperial 3’ 6”  (3 feet, 6    

 inches)
Battery life (while plugged in) 

Unlimited - mains powered & battery backup   

 

(9,000 hours, 1 year  while unpowered) 

Battery type 

Unit contains one 9V Alkaline batteries 

 

(E-Block, PP3, 1604A) 

Communications interface type 

RS-232 serial, baud of 19,200 

Electrosoft software 

Windows (9x, 2K, ME, NT, XP, Vista, Windows   

 

7); 1024 x768 min resolution 

Environmental (temp & sealing) 

-20C to +40C or +14°F to +104°F  – Indoor or 

 

protected environment only, IP65, NEMA 4X

Dimensions & weight 

Metric  145 x 90 x 45mm & 400g

 

Imperial – 5.5” x 3.5” x 2” & 1lb 

Standards 

Recording - EN50160: 1994 -  CAT II, 

 maximum 

Technical specifications

(subject to change without notice)

Отзывы: