USER MANUAL 16-2028 

Rev. 04/2017

• Set the switch [S3] to position 1, the device is then in standby mode (the green light [L1] should flash and a 
logo should appear in the display [L2]).

• Press the Standby button [S1] to switch on the device (the green light is lit and a logo indicating insertion of 
a light cable appears in the display [L2]). Pressing the Standby button again will reset the device to standby.

• Push the light cable into the aperture provided [C1]; you should hear a click as it engages. A logo indicating 
that the device is in “iris” mode appears.

• Connect the other end of the light cable to your endoscope. Before setting up an endoscope (or fibroscope) 
in front of the camera lens, it is advisable to check the condition of the endoscope (distal lens or clean 
eyepiece).

• Press the adjustment knob [S2] or turn it in order to release the light.

The light source is fitted as standard with an adapter for a Storz-type light cable. A version of this   

    

         device that is compatible with Olympus-type light cables is also available.

If no light cable is connected to the device when the latter is switched on, a logo will display this 

             information on the screen. Then you only need to connect up a light cable in order to see the “iris” 
             logo and use the device. 

6. OPERATION                                                                                                                                                 

6.1 SETTING THE LIGHT INTENSITY                                                                                                                 

After insertion of the light cable, a logo indicating the “iris” mode will be displayed on the screen [L2]. Pressing
or turning the adjustment knob [S2] enables the user to exit this mode and to release the light. A bar graph
indiquates the level of intensity will then appear [L2]. Turning the adjustment knob [S2] clockwise will increase
the light intensity and turning it anti-clockwise will reduce the intensity.
An empty bar graph indicates that the source is completely dead while a full bar graph shows that it is 
delivering maximum light intensity.

The LED takes about 10 seconds to stabilise its colour temperature. It is advisable to wait for this 

             length of time before setting the white balance on the camera.

It is also advisable to do a white balance whenever there is a change of intensity setting.

6.2 POWER LEVEL MEMORY                                                                                                                             

To put the LED source in “iris” mode, simply press the adjustment knob [S2]. Pressing the same button again
will restore light power to the previous setting. In the same way, if the LED source has been disconnected
from its power supply it will start up again with the light power of the previous setting.

7. DESCRIPTION OF BACK PANEL

 

      

               

 

                        

 

    

               

 

             

 

             

 

             

 

             

 

       

7.1 DESCRIPTION OF VENTS                                                                                                                             

The vents [A] located on the back panel of the device must not be obstructed as this can cause a risk of 
overheating.
The light source has an automatic safety device which stops the lighting function if the internal temperature is
too high. A pictogram indicating whether this safety system is activated will be displayed on the screen [L2].

PAGE 7

 OF 14

Содержание 16-2028

Страница 1: ...USER MANUAL 16 2028 LED LIGHTSOURCE ...

Страница 2: ...manufacturer The manufacturer will appreciate any errors or anything unclear in this operating manual being pointed out to us by users of our products Due to the continuing progress and development of our products we reserve all rights for technical alterations Rev 04 2017 SERVICE ADDRESS Ackermann Instrumente GmbH Eisenbahnstrasse 65 67 78604 Rietheim Weilheim Germany Tel 49 0 7461 96617 0 Fax 49...

Страница 3: ...STANDARDS AND REGULATIONS 5 5 INSTALLATION OF THE LIGHTSOURCE 6 6 OPERATION 7 7 DESCRIPTION OF BACK PANEL 7 8 RECOMMENDED DECONTAMINATION PROCEDURE 8 9 AFTER SALES SERVICE AND MAINTANCE 10 10 TROUBLESHOOTING 12 11 TECHNICAL SPECIFICATIONS 13 12 ELECTROMAGNETIC COMPATIBILITY 13 13 SYMBOLS 14 PAGE 3 OF 14 ...

Страница 4: ...lumination power and precise manual adjustment of light intensity make this the perfect multidisciplinary medical instrument This device comprises A power cord A user manual A quick start guide Optional accessories Universal light cable Adapters for universal light cable source side Storz and Olympus and endoscope side Storz Olympus Wolf S N ACMI Stryker We advise selecting the following diameter ...

Страница 5: ...vice should only be connected to an earthed power supply This device must not be modified without the manufacturer s authorisation If the medical device is modified an inspection and test must be performed to ensure the medical device complies with the safety instructions Before use check with the manufacturer that your endoscope is compatible with this device This device must be used on individua...

Страница 6: ...turer s contact details please refer to the last page of the manual 4 4 END OF LIFE This appliance is marked according to the European Directive 2002 96 EEC on Waste Electrical and Electronic Equipment WEEE By ensuring this product is disposed of correctly you will help prevent potential negative consequences for environment and human health which could otherwise be caused by inappropriate waste h...

Страница 7: ...e light cable a logo indicating the iris mode will be displayed on the screen L2 Pressing or turning the adjustment knob S2 enables the user to exit this mode and to release the light A bar graph indiquates the level of intensity will then appear L2 Turning the adjustment knob S2 clockwise will increase the light intensity and turning it anti clockwise will reduce the intensity An empty bar graph ...

Страница 8: ...hods and or tools are chosen it remains the sole responsibility of the personnel involved This device is not autoclavable The existing alkaline solutions for disinfection of certain medical devices are PROHIBITED for disinfecting this device 9 AFTER SALES AND MAINTANCE No special maintenance is required for this device Note incorrect or faulty use is not covered by the guarantee If a problem persi...

Страница 9: ...position and it can be re used Check that there is enough space around the source to ensure adequate cooling 15 cm all around the device Check that nothing is obstructing the air vents on the back and underneath the source The light source is in iris mode Press the adjustment knob S2 or turn it in order to release the light If the fault persists and the device needs to be returned to our After Sal...

Страница 10: ...xygen or nitrous oxide Standards Electrical safety class 1 type CF Complies with the European Directive 93 42 EEC Class I Complies with the international standards IEC 60601 1 IEC 601 2 18 IEC 60417 and EN 980 This product is fitted with group 1 LEDs in accordance with the standard IEC 62471 Do not look directly into the light to avoid any risk of eye damage 12 ELECTROMAGNETIC COMPATIBILITY 12 1 G...

Страница 11: ...USER MANUAL 16 2028 Rev 04 2017 12 2 GUIDE AND DECLARATION OF THE MANUFACTURER ELECTROMAGNETIC IMMUNITY PAGE 11 OF 14 ...

Страница 12: ...USER MANUAL 16 2028 Rev 04 2017 12 3 GUIDE AND DECLARATION OF THE MANUFACTURER ELECTROMAGNETIC EMISSIONS PAGE 12 OF 14 ...

Страница 13: ...USER MANUAL 16 2028 Rev 04 2017 12 4 RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATION SYSTEMS AND THIS PRODUCT PAGE 13 OF 14 ...

Страница 14: ...USER MANUAL 16 2028 Rev 04 2017 13 SYMBOLS PAGE 14 OF 14 ...

Отзывы: