background image

Содержание AI-CP2H

Страница 1: ......

Страница 2: ......

Страница 3: ...lity and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information WELCOME EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA 3 ...

Страница 4: ...7 UPC A 819137020047 854759004976 854759004983 854759004990 819137020009 819137020016 854759004501 854759004518 819137020023 819137020030 819137020054 819137020061 CONTROLLER 12 CLOUDPLATE T1 CLOUDPLATE T1 N CLOUDPLATE T2 CLOUDPLATE T5 CLOUDPLATE T6 CLOUDPLATE T7 CLOUDPLATE T7 N CLOUDPLATE T9 CLOUDPLATE T9 N CLOUDPLATE T12 RACK ROOF FAN ...

Страница 5: ...ntact Manual Index Rack Cooling Guide Key Features Product Contents Installation Programming Connecting More Fans Other AC Infinity Products Warranty Page 3 Page 5 Page 6 Page 7 Page 8 Page 9 Page 12 Page 19 Page 20 Page 21 5 ...

Страница 6: ...AKE AND EXHAUST All rack fan systems should contain an intake and exhaust variable To assist with natural convection position fans near the top of the rack configured to exhaust out the warm air and fans near the bottom to push in cool air OPTIMIZING AIRFLOW To optimize airflow circulation we reco mmend using blank panels to fill the empty spaces on the rack This increases the efficiency of the fa...

Страница 7: ...OTOR PWM controlled motor features precise speed control reduced rotor noise and runs on energy efficient DC voltage SMART CONTROLLER LCD display enables temp monitoring thermal control speed control alarms and SMART energy mode EXPANSION PORTS Each unit contains a DC connector port which can be used to control another rack fan unit or rack roof fan kit 7 THERMAL PROBE The corded precision sensor ...

Страница 8: ...T7 CLOUDPLATE T7 N CLOUDPLATE T9 CLOUDPLATE T9 N AI CP2L AI CP2H AI CPT9 AI CPT9 N RACK ROOF FANS CONTROLLER 12 CLOUDPLATE T12 AI RRF7 AI CTB12 AI CPT12 Roof Fans Screws Power Adapter Controller Probe Screws Power Adapter Controller Probe Roof Fans Screws Adapter Cooling Fan System 1 THERMAL PROBE 1 MOUNTING SCREWS 4 ZIP TIES 1 POWER ADAPTER 1 ...

Страница 9: ... to page 6 for a guide on the best fan placement to optimize cooling STEP 2 Use a screwdriver and the included screws to secure the fan unit onto your rack Depending on the rack rail type you may need to install cage nuts first Please note that some rack rails may come pre threaded with another screw size 9 ...

Страница 10: ...e DC connector of the AC power adapter into the port labeled POWER on the backside of the rack fan unit STEP 4 Plug the AC power adapter into a standard power outlet Please check that the LCD screen is now displaying all contents and that the settings can be changed The probe s temperature readings will not yet be visible 10 ...

Страница 11: ...he rack fan unit Please check that the LCD screen now displays the probe s temperature readings 11 STEP 6 Secure the head of the probe onto the rack using the included cable ties We recommend positioning the probe near your hottest equipment and away from any fans that can distort the probe s temperature readings ...

Страница 12: ...T6 CLOUDPLATE T12 CLOUDPLATE T7 CLOUDPLATE T7 N F o F o F o F o SETTING PROBE AUTO ALARM SPEED BUFFER 1 2 4 3 5 6 7 8 9 10 CLOUDPLATE T9 CLOUDPLATE T9 N F o SETTING PROBE F o F o F o AUTO ALARM SPEED BUFFER 1 2 4 5 6 7 8 9 10 3 1 3 2 4 5 6 7 8 9 F o F o PROBE F o F o ALARM SPEED BUFFER SETTING AT 10 ...

Страница 13: ...P Shows the temperature you have set for the fan system to trigger in AUTO and SMART Mode which share the same set temp 6 ALARM TEMP Shows the temperature that you set the fan s alarm system to trigger Please see page 16 for more information 7 FAN SPEED The settings for the max speed the fans can reach Shows what speed the fans are currently running at Six speeds are available 8 BUFFER The buffer ...

Страница 14: ... fan Which ever speed is designated in this mode will also be the speed used in AUTO Mode and the max speed of the fans in SMART Mode AUTO MODE This is the thermostat setting where the fans will start running when the PROBE temperature reaches or surpasses the SETTING temperature The SETTING temperature can be designated by pressing the up and down buttons while in this mode Once the fans start ru...

Страница 15: ... BUFFER SMART MODE This is the energy saving mode where the fans will change speed depending on the temperature The SETTING temperature can be designated by pressing the up and down triangle buttons while in this mode For every 2 F increment that the PROBE temperature is below the SETTING temperature the speed of the fans will decrease by one level This increment can be changed to 4 F 6 F or 8 F b...

Страница 16: ... Mode so please remember to exit ALARM Mode once the alarm has been set When the alarm is triggered the fan s will run at max speed regardless of the setting and will make an audible beep every three seconds This will keep occurring until the temperature drops below the ALARM temp or if any buttons are pressed The alarm can be disabled by pressing the up triangle button until the temperature is at...

Страница 17: ...LOCK Holding the MODE button for three or more seconds will lock the controller The controller will still work as programmed however pressing any buttons will not have an effect and will cause the screen lock icon to flash and will make an audible beep three times a second This option was designed to prevent your controller settings from being changed by accident Holding the MODE button again for ...

Страница 18: ... will flash when any buttons are pressed while the controller is locked Please see page 17 for more information ALARM ALERT The alarm alert icon will flash when the probe temperature reaches or exceeds the alarm temperature you have set Please see page 16 for more information on setting up the alarm FAN FAILURE ALERT The fan failure icon will flash when one or more fans in the CLOUDPLATE cooling s...

Страница 19: ...ust be set to SPEED Settings Mode it s speed set to max and the alarm turned off Connected fans will share the same temperature control settings CONTROLLER 12 The Controller 12 can also control CLOUDPLATE Series fan units and RACK ROOF FANS in the exact same way as described above In addition it can also control AIRPLATE Series cabinet fans and MULTIFAN Series component USB fans On the backside pl...

Страница 20: ... S6 AIRCOM S7 AIRCOM S8 AIRCOM S9 AIRCOM T8 AIRCOM T9 MODEL AI ACS6 AI ACS7 AI ACS8 AI ACS9 AI ACT8 AI ACT9 DIMENSIONS 4 6 x 4 6 x 1 3 in 6 3 x 6 3 x 1 3 in 8 4 x 4 4 x 1 3 in 11 7 x 6 1 x 1 3 in 17 5 x 6 1 x 1 3 in PRODUCT AIRPLATE S1 AIRPLATE S3 AIRPLATE S5 AIRPLATE S7 AIRPLATE S9 MODEL AI CFS80BA AI CFS120BA AI CFD80BA AI CFD120BA AI APS9 AIRPLATE SERIES The AIRPLATE series is designed to cool ...

Страница 21: ...he warranty program goes into effect on the date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect installation such a...

Страница 22: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Страница 23: ......

Страница 24: ...www acinfinity com ...

Отзывы: