Setup
°F or °C
Changes the temp scale
and setpoint scale
Offset Adjustment
Adjusts the temp output
up to ± 5°
Temp Output Range
Changes the temp output
range for analog outputs
Temperature DA/RA
Changes the temp output
to direct or reverse acting
for Analog outputs
Temperature Test
Sets the temp output to
40°F, 72°F, or 104°F for
testing the output
Temperature Tenths
Removes the tenths place
from the temp
display
Temp Setpoint Midpoint
Sets the temperature
setpoint midpoint
Temp Setpoint Range
Changes the temp
Setpoint range
Temp Setpoint Keylock
Locks out the user from
making any setpoint
changes
Temp Setpoint Options
Temp Setpoint
Calibration
Selects between two
different setpoint outputs,
only supported for special
orders
Temp Setpoint DA/RA
Changes the setpoint
output to direct or reverse
acting for analog outputs
Temp Setpoint Display
Sets how the setpoint is
displayed, either an offset
or temperature can be
displayed
Sensor
Display
The full setup menu with descriptions of all the options are
shown above. The setup menu will change depending on
the configuration ordered. Only the menu options that
apply to the configuration ordered will be shown on the
unit.
Press and hold SETUP for 5 seconds or press the UP arrow
and DOWN arrow for 10 seconds to enter the Setup mode.
Press UP/DOWN arrows to scroll through top level menus.
Press SELECT to enter into Options Menus
Press UP/DOWN to scroll through Options Menu
Press SELECT to chose and save option in Options Menu
A full size version of this diagram can be found at
www.workaci.com
Setup
Setup
Setup
Setup
Setup
Temperature Options
(blank)
Setup
offset
°C °F
Setup
O Ut
Setup
dA rA
Setup
tE nth
Setup
tE St
Setup
(blank)
Setup
setpoint
rA ngE
Setup
setpoint
LO C
Setup
setpoint
CA L
Setup
setpoint
dA rA
Setup
setpoint
dI SP
Setup
setpoint
RH Offset
Adjusts the RH output up
To ± 5% RH
RH Test
Sets the output to 0%,
50%, & 100% for testing
the output
RH DA/RA
Changes the RH output to
direct or reverse acting
RH Tenths
Removes the tenths place
from the RH display
RH Setpoint Midpoint
Sets the RH setpoint
midpoint
Temperature Menu
RH Menu
RH Setpoint Options
Display Menu
Fan Menu
System Menu
Additional Options Menu
RH Setpoint Range
Sets the RH setpoint range
RH Setpoint Keylock
Locks out the user from
making setpoint changes
RH Setpoint DA/RA
Changes the setpoint
output to direct or reverse
acting for analog outputs
RH Setpoint Display
Sets how the setpoint is
displayed, either an offset
or RH can be displayed
Display Setup
Changes what is displayed
and the location on the
display
Backlight Brightness
Sets the backlight
brightness
Backlight Duration
Sets the length of time the
backlight stays on**
Setpoint Always On
Sets the setpoint to always
be displayed
Fan On or Off
Hides the fan display
Fan Keylock
Locks out the user from
making fan adjustments
System On or Off
Hides the system display
System Keylock
Locks out the user from
making system
adjustments
Setup Lockout
Locks out the setup menu.
To get into the setup menu
when locked, press the up
and down arrows for 5
seconds
Factory Reset
Resets the unit to factory
defaults
Software Version
Displays the software
version number
RH Options
Display Options
Fan Options
Systems Options
Additional Options
Sensor
Display
Sensor
Display
Sensor
Display
Sensor
Display
dI SP
Setup
br ite
Setup
du rtn
Setup
SP
Setup
dI SP
Setup
L OC
Setup
dI SP
Setup
L OC
Setup
LO C
Setup
rE SEt
Setup
SI On
Setup
(blank)
Setup
offset
tE St
Setup
dA rA
Setup
te nth
Setup
(blank)
Setup setpoint
rA ngE
Setup setpoint
Lo C
Setup
dA rA
Setup setpoint
dI SP
Setup setpoint
Sensor
Display
SELECT
** Increasing the time the backlight stays on will reduce the life of the backlight