Setup 

 

°F or °C 

 Changes the temp scale 
 and setpoint scale

 

 
  

Offset Adjustment 

 Adjusts the temp output 
 up to ± 5° 

 
  

Temp Output Range 

 Changes the temp output 
 range for analog outputs 

 
  

Temperature DA/RA 

 Changes the temp output 
 to direct or reverse acting  
 for Analog outputs 

 
  

Temperature Test 

 Sets the temp output to     
 40°F, 72°F, or 104°F for  
 testing the output 

 
  

Temperature Tenths 

 Removes the tenths place  
 from the temp

 

display

 

 
 

 

Temp Setpoint Midpoint 

 Sets the temperature 
setpoint midpoint 

 

Temp Setpoint Range 

 Changes the temp 
 Setpoint range 

 
 

Temp Setpoint Keylock 

 Locks out the user from  
 making any setpoint 
changes 

 
 

 

Temp Setpoint Options 

 

 

Temp Setpoint 

Calibration 

 Selects between two           
different setpoint outputs,     
only supported for special 
orders 

 

 

Temp Setpoint DA/RA 

 Changes the setpoint 
output  to direct or reverse 
acting for analog outputs 

 

 

Temp Setpoint Display 

 Sets how the setpoint is  
displayed, either an offset 
or   temperature can be    
displayed 

 

 Sensor 
Display 

The full setup menu with descriptions of all the options are 
shown above.  The setup menu will change depending on 
the configuration ordered.  Only the menu options that 
apply to the configuration ordered will be shown on the 
unit. 

 

Press and hold SETUP for 5 seconds or press the UP arrow 
and DOWN arrow for 10 seconds to enter the Setup mode. 

Press UP/DOWN arrows to scroll through top level menus. 

Press SELECT to enter into Options Menus 

Press UP/DOWN to scroll through Options Menu 

Press SELECT to chose and save  option in Options Menu 

 

A full size version of this diagram can be found at 
www.workaci.com 

Setup 

Setup 

Setup 

Setup 

Setup 

 Temperature Options 

 

(blank) 

 

 Setup 
 offset 

°C   °F 

 

 Setup 

 O   Ut 

 

 Setup 
 

 dA   rA 

 

 Setup 

 tE    nth 

 

 Setup 

 tE    St 

 

 Setup 

 (blank) 

 

 Setup 
 setpoint 

 

 rA  ngE 

 

 Setup  
setpoint 

 

 LO     C 

 

 Setup  
setpoint 

 CA      L 

 

 Setup  
setpoint 

 

 dA      rA 

 

 Setup  
setpoint 

 dI     SP 

 

 Setup  
 setpoint 

 

 

RH Offset 

 Adjusts the RH output up  
 To ± 5% RH 

 
  

RH Test 

 Sets the output to 0%,  
 50%, & 100% for testing 
the output 

 
  

RH DA/RA 

 Changes the RH output to  
 direct or reverse acting 

 
 

 

RH Tenths 

 Removes the tenths place  
 from the RH display 

 
 

 

RH Setpoint Midpoint 

 Sets the RH setpoint  
 midpoint 

 
 

 Temperature Menu 

 RH Menu 

 RH Setpoint Options 

 Display Menu 

 Fan Menu 

 System Menu 

Additional Options Menu 

 

RH Setpoint Range 

 Sets the RH setpoint range 

 
  

RH Setpoint Keylock 

 Locks out the user from   
 making setpoint changes 

 
  

RH Setpoint DA/RA 

 Changes the setpoint   
 output to direct or reverse  
 acting for analog outputs 

 
  

RH Setpoint Display 

 Sets how the setpoint is  
 displayed, either an offset  
 or RH can be displayed 

 
 

 

Display Setup 

 Changes what is displayed  
 and the location on the  
 display 

 
  

Backlight Brightness 

  Sets the backlight  
  brightness 

 
  

Backlight Duration 

 Sets the length of time the  
 backlight stays on** 

 
  

Setpoint Always On 

 Sets the setpoint to always 
be displayed 

 
 

 

Fan On or Off 

 Hides the fan display 

 
  

Fan Keylock 

  Locks out the user from  
 making fan adjustments 

 
 

 

System On or Off 

 Hides the system display 

 
  

System Keylock 

 Locks out the user from  
 making system  
 adjustments 

 
 

 

Setup Lockout 

 Locks out the setup menu.  
To get into the setup menu 
when locked, press the up 
and down arrows for 5 
seconds 

 
 

 

Factory Reset 

 Resets the unit to factory 
defaults 

 
  

Software Version 

 Displays the software  
 version number 

 
 

 RH Options 

 

 Display Options 

 

 Fan Options 

 

 Systems Options 

 

 Additional Options 

 

 Sensor 
Display 

 Sensor 
Display 

 Sensor 
Display 

 Sensor 
Display 

 dI   SP 

 

 Setup 

 br   ite 

 

 Setup 

du  rtn 

 

 Setup 

 SP 

 

 Setup 

 dI   SP 

 

 Setup 

 L    OC 

 

 Setup 

 dI   SP 

 

 Setup 

 L   OC 

 

 Setup 

 LO    C 

 

 Setup 

 

 rE   SEt 

 

 Setup 

 

 SI   On 

 

 Setup 

 

 (blank) 

 

 Setup 
 offset 

 tE   St 

 

 Setup 

 dA   rA 

 

 Setup 

 te   nth 

 

 Setup 

 (blank) 

 

 Setup setpoint 

 rA  ngE 

 

 Setup setpoint 

 Lo   C 

 

 Setup 

 dA   rA 

 

 Setup setpoint 

 dI   SP 

 

 Setup setpoint 

 Sensor 
Display 

SELECT 

** Increasing the time the backlight stays on will reduce the life of the backlight 

Содержание TUC2

Страница 1: ...pports single temperature sensor operation for several common sensor types and it provides the flexibility to choose from numerous setpoint output options The TUCH2 supports relative humidity output i...

Страница 2: ...ction box using the hardware provided After wiring attach the cover to the base and turn out the hex screw until the cover cannot be removed Wiring A 16 to 22 AWG shielded cable is recommended for all...

Страница 3: ...output S3 3 5mm phone jack shield RH RH signal to controller RHS RH set point or system signal to controller Communication Jack Wiring Modular Telephone Jack Before mounting the base to the wall make...

Страница 4: ...tip and shield The number of wires needed depends on the application OPERATION Keypad The keypad comes in a 2 button 3 button 4 button 5 button or 6 button version A 6 button keypad is needed for fan...

Страница 5: ...ny key is pressed and will turn off 10 seconds after the last key press Setpoint Mode Press or to get into setpoint mode and change the setpoint If a temperature and RH setpoint are used pressing or a...

Страница 6: ...de Once in the setup menu or will scroll through the setup menu Press or and to enter menus Press or and to save a menu selections Press to return to the previous menu If no keys are pressed for 15 se...

Страница 7: ...Setup blank Setup setpoint rA ngE Setup setpoint LO C Setup setpoint CA L Setup setpoint dA rA Setup setpoint dI SP Setup setpoint RH Offset Adjusts the RH output up To 5 RH RH Test Sets the output t...

Страница 8: ...stive Output Models Temperature Accuracy 1 F 0 56 C Operating Temp Range 40 F to 104 F 5 C to 40 C Operating Environment 32 F to 122 F 0 C to 50 C 0 to 95 RH non condensing RH Measurement Range 0 to 1...

Отзывы: