aci P51 Series Скачать руководство пользователя страница 1

Automation Components, Inc.

2305 Pleasant View Road  |  Middleton, WI 53562

Phone:

 1-888-967-5224  |  

Website:

 workaci.com

Page 1

Version: 3.0

I0000792

GENERAL INFORMATION

The P51 Series is designed to provide excellent 

accuracy and reliability in commercial, industrial, 

and process control applications where performance 

is critical.  The P51 Series is available in three 

pressure sensing types: Gage (PSIG), Sealed Gage 

(PSIS) and Absolute (PSIA). Gage (PSIG) sensors 

measure pressure relative to ambient pressure 

through a port that is open to the atmosphere, and 

are used in lower pressure applications where 

measurement in a vacuum is not required. Sealed 

sensors (PSIS) measure pressure relative to a port 

that is connected to a sealed perfect vacuum 

chamber.  Sealed pressure transducers are calibrated 

to have 0.5 VDC, 1 VDC or 4 mA respectively at +14.5 

PSIA.  Absolute sensors measure pressure relative to 

a perfect vacuum pressure (0 PSIA), which doesn’t 

change regardless of temperature, location or any 

other ambient conditions such as weather.

OPTIONAL ACCESSORIES

Pressure Snubber

ACI recommends the use of the A/0.25” Snubber 

(Water or Air/Gas) with all P51 series sensors.  The use 

of a pressure snubber is a cost-effective solution that 

can extend the life of your sensor by smoothing out 

pressure spikes, surges and pulsations, and prevent 

debris from collecting in the sensor diaphragm 

opening.  The A/0.25” Snubbers are made of 316 

Stainless Steel and should be used with compatible 

materials.

Syphons

The A/Syphon must be used to protect the sensor 

from extreme operating temperatures when the 

operating temperature of the steam being 

monitored is higher than the maximum operating 

temperature of the pressure sensor.  There are three 

bend configurations available (90˚, 180˚, and 270˚) to 

allow the mounting of the sensor vertically away from the main pipe.  

NEMA 4 Enclosure

ACI recommends the use of a NEMA 4 enclosure to protect the gage pressure sensor in applications where 

debris and moisture could contact the sensor or electrical connections.  The A/GP-(xx)-NEMA 4 GP Series 

pressure sensor is mounted in a NEMA 4 Rated, steel enclosure with one ½” conduit knockout.  A ¼” male 

NPT Stainless Steel fitting is provided for installation to your pipe, tank, or reservoir.

FIGURE 1: 

PRODUCT DIMENSIONS

P51 SERIES GAGE PRESSURE

TRANSDUCER

Installation & Operation Instructions

Phone:

 1-888-967-5224

Website:

 workaci.com

I24

Packard

2.56” (65.02mm)

24.00” 

(609.60mm)

0.71” 

(18.03mm)

1.03” 

(26.16mm)

2.77” (70.36mm)

Ø0.87” 

(22.07m

m)

0.71” 

(18.03mm)

1.06” 

(27.00mm)

0.78” (19.81mm)

7/8” HEX

0.88”

(22.35mm)

Содержание P51 Series

Страница 1: ...pressure snubber is a cost effective solution that can extend the life of your sensor by smoothing out pressure spikes surges and pulsations and prevent debris from collecting in the sensor diaphragm opening The A 0 25 Snubbers are made of 316 Stainless Steel and should be used with compatible materials Syphons The A Syphon must be used to protect the sensor from extreme operating temperatures whe...

Страница 2: ...kPa we recommend the use of a sealant such as Loctite Hydraulic Sealant Do not use excessive amounts of sealant or you might block the pressure going into the transducer Install the device using a wrench on the hex flats provided Do not use a strap wrench on the body When installing the sensor the torque limit will vary see the Torque Limits Table for more detail Do Not over tighten Overtightening...

Страница 3: ... Tube on I24 Lead Style Only Optional 250 Ohm or 500 Ohm Load Resistor for a 1 5 VDC or 2 10 VDC Output SHIELD POWER SUPPLY 13 TO 30 VDC AUTOMATION PANEL AI1 FIGURE 4 VOLTAGE WIRING DIAGRAM COM RED WIRE WHITE WIRE BLACK WIRE Note Clear Vent Tube on I24 Lead Style Only AI1 AI2 VDC Analog Input CLEAR VENT TUBE SHIELD POWER SUPPLY 5 TO 30 VDC AUTOMATION PANEL AI1 VOLTAGE OUTPUT CONNECTIONS Connect th...

Страница 4: ...ci com Page 4 Version 3 0 I0000792 PROBLEM No Output or Output Signal Reading Low Output Signal is Inaccurate SOLUTION S ConfirmtheDCsupplyvoltageis 0 5 to 4 5 VDC Output Only 5 00 VDC 0 500 VDC 4 to 20 mA and 1 to 5 VDC Outputs Only 8 to 30 VDC No Load 4 20 mA Output 250 Ohm Load 13 to 30 VDC 500 Ohm Load 18 to 30 VDC Disconnect the sensor from the line to ensure No debris or sediment isblockingt...

Страница 5: ...C 40 to 176ºF 40 to 80ºC 304L or 316L Stainless Steel See Datasheet for more details 0 to 95 RH non condensing Any gas or liquid compatible with 304L or 316L Stainless Steel All Ports except U and Y 150 lbs in 16 95 Nm Ports U and Y 120 lbs in 13 56 Nm Packard Connector Cables ordered separately per Ordering Grid on back of data sheet 124 24 Lead Length PVC Jacketed Cable 18 0 823 mm2 or 24 AWG 0 ...