4. DSIM Controller Operation Instruction Guidelines
Switch
Function
Description
+
Increase
In MGC Mode, Click to increase RF output level
(See Note 1)
In AGC Mode, no function
In TGC Mode, Click to increase cable length value
-
Decrease
In MGC Mode, Click to decrease RF output level
(See Note 1)
In AGC Mode, no function
In TGC Mode, Click to decrease cable length value
Mode
Mode Change
In MGC mode, Click to go to Align Mode to load
controller channel setting, DSIM module will then
automatically switch to AGC mode
In AGC Mode, Click to return to TGC Mode
In TGC Mode, Click to go to MGC Mode
Note 1:
Making adjustment to the output levels is only recommended when setting up the
DSIM modules in temperatures bellow 32ºF / 0ºC or above 104ºF / 40ºC.
5. DSIM Controller Status LED Essentials
LED Blinking Pattern
Indications
Quick Blue / Red Blinks
DSIM controller to module syncing process -
Occurs when controller is installed into the DSIM
module.
Aligning process: in progress
Steady on Blue
In MGC Mode
Series of Blue Blinks
In AGC Mode
Steady on Purple
In TGC Mode