Installation
40
External emission light
Pin 22
EMISSION
24 V, max. 200 mA, protected by polyfuse.
Pin 22 carries 24 V when the shutter is open.
The connected emission warning light signals danger from laser radiation.
Emission ready
Pin 3
READY
24 V, max. 200 mA, protected by polyfuse.
This output produces a composite signal of all possible error states.
The output is set when all components function within normal parameters and the laser is
ready for operation.
This signal can be processed both optically and electronically.
This output is an essential aid, particularly for use in production lines.
Inputs and outputs
Pin 5 to 12
IN1 to IN8
24 V, 3.5 mA
Control inputs for the PLC connector
Pin 23 to 30
OUT1 to OUT8
24 V, max. 0.5 A
WARNING
DANGER OF INJURIES AND/OR RISK OF PROPERTY DAMAGE FROM
LASER RADIATION!
Wiring this output is specified for operation in accordance with a class
4 laser.
!