Safety
16
General
•
Read the operating instructions and always keep them in an accessible place.
•
Do not mark any easily flammable or combustible materials.
•
Do not transport, store or operate the device in a vertical position.
There is a risk of damaging optical components.
Initial start-up
•
The ambient temperature must lie within the range of > 20 °C and < 30 °C. The con-
densation temperature as a function of the momentary relative air humidity must be
< 20 °C. You will find an instruction for estimating the momentary value in the appendix.
•
Ensure that the relative air humidity does not exceed 85%.
•
Never start the device immediately after large temperature changes. Condensation wa-
ter may damage the device.
•
Ensure that an adequate air supply can be provided at the location of the supply unit