background image

3

1. Advisement

 

WARNING

Always have the unit installed by the store it was purchased from.

 

Improper connections and/or installation could result in electrical shack,

fire or other serious injury or damage.

Do not place the unit on an unstable surface.

 

Always checks the strength and stability of the installation location.

 

A falling unit will result in damage and could cause serious injury

Never disassemble or attempt to repair or modify the unit.

 

Disassembly by untrained personnel could result in serious electrical

shock, fire and/or malfunction.

Never use in locations where combustible materials are used.

 

The unit should never be used where combustible materials, such as

gases, are being used.

 

Fire, explosion or other serious accidents could occur.

Never touch electrical connections with wet hands.

 

Touching electrical connections with wet hands could result in serious

electrical shock.

Never expose the unit to water.

 

If the unit becomes wet, turn off the power and unplug it immediately.

 

Stop using the unit if it becomes wet and contact your nearest dealer.

Never use the unit if there is an abnormality.

 

Turn off the power and unplug the unit immediately if there is any type of

abnormality, such as a strange smell or smoke.

 

Continuing to use a unit that is not operation properly could result in

serious injury or damage ta the unit.

Always use the designated power supply.

 

Failure to use the proper power supply could result in fire, electrical shock,

serious injury and/or damage.

 

Always uses the designated power supply.

Always handle the connecting cords properly.

 

Never damage or modify the connecting cords.

 

Never pull on the connecting cord, expose them to extreme heat and/or

place heavy objects on top of them.

 

Failure to follow these warnings could result in fire, electrical shock or

other damage or injury.

 

CAUTION

Always use the unit indoors.

 

The unit should never be used outdoors, or in any place where it will be

exposed to rain or other extremes of moisture.

 

Direct exposure to water will result in rust and will damage the unit.

Never use in environments that have heavy concentrations of dust,
smoke, steam or humidity.

 

Environments such as these could result in fire, electrical shock or other

serious damage or injury.

Never place the unit in extremes of high or low temperatures.

 

Extreme temperatures will damage the unit.

 

Always use within an operating range of 0 °C to 40 °C.

Never mount in areas exposed to direct sunlight.

 

Direct sunlight can also discolor the unit and cause other damage.

Never expose the unit to impact.

 

Strong impact may seriously damage the unit.

 

FOR PROPER OPERATION

Never install the unit yourself.

 

The unit should be installed by trained personnel.

This product has been designed and manufactured in accordance with the
harmonized European standards, following the provisions of the below stated
directives.

Electromagnetic Compatibility Directive 89/336/EEC

 (EN 61000-3-2:1995,

EN 61000-3-3:1995, EN 50081-1:1992, EN 50082-1:1997).

This devise complies with part 15 of the FCC rules operation is subject to the
following two conditions: (1) This device may not cause harmful  interterence
and (2) This device must accept any interference received including
interference that may cause undesired operation.

Содержание AT6SD

Страница 1: ...AT6SD KEYBOARD CONTROLLER Instruction manual ref Mi 3146 Please read carefully and completely this manual before install the product and keep for future reference ...

Страница 2: ...f Camera 4 Camera Setup How to enter into OSD menu 5 Preset Point 6 Swing 7 Group 8 Tour 9 Spiral Function 10 PTZ trace 11 Camera Remote Reset 12 Brightness Control of LCD 13 Alarm On Off 6 Maintenance and Mending 19 7 Connections 20 8 General Specifications 21 1 Controller 2 Junction box 3 DC Power Supply 4 Camera Control Interface 5 Constitution of Junction box pin 6 Constitution of pin between ...

Страница 3: ...wer supply Always handle the connecting cords properly Never damage or modify the connecting cords Never pull on the connecting cord expose them to extreme heat and or place heavy objects on top of them Failure to follow these warnings could result in fire electrical shock or other damage or injury CAUTION Always use the unit indoors The unit should never be used outdoors or in any place where it ...

Страница 4: ...nd tour Features Control up to maximum 255 cameras Several keyboards can be used to simultaneous control of a camera Easy operation of pan tilt with the joystick Same effect as 64 fixed surveillance camera by setting a maximum of 64 preset points Pan tilt swing function Group surveillance function select preset points routinely and repeatedly Tour surveillance function repeated practice of many gr...

Страница 5: ...ts and AUX1 only for receiver unit GROUP Button This button is used to monitor the preset pionts sequentially TOUR Button This button is used to monitor the groups sequentially SET Button This button is used to start the setting mode of various function Z I Zoom In Z O Zoom Out Button Operate the zoom control of camera AUX Auxiliary Buttons These buttons are used to control of Auto Pan AUX1 and ot...

Страница 6: ...monitor can be viewed Downward Tilt When joystick is operated downward it will make the camera move down and the lower part of the color monitor can be viewed Left Pan When joystick is operated to leave it will make the camera move to left and the left part of the color monitor can be viewed Right Pan When joystick is operated to right it will make the camera move to right and the right part of th...

Страница 7: ...ut 2 3 sec 5 Preset Point The controller makes to memorise 64 sets of the individual preset position for each camera The memorised preset point is available in resetting of power and it can be changed Starting the preset mode SET Keypad 1 64 PST This mode enable pan tilt and zoom focus far near work by joystick Thus it can move the point of setting After put and stop it in place you want to survei...

Страница 8: ... Keypad 1 64 ENT Swing time The standby time dwell time before starting from A or B sec Swing speed The moving speed from A to B 1 sec 64 sec Start and stop of swing Execution 1 Pan 2 Tilt SWING Stop SWING or Joystick 7 Group It is repetitive surveillance function which sequentially switch to multiple of preset points with the speed and standby time designated 64 preset points in maximum can be re...

Страница 9: ...e supported only at speed dome camera the fixed pan speed and tilt speed is operated at the same time that can make a spiral function 10 PTZ trace The controller is made to meet to the function in speed dome camera This function makes to memorise P T Z movement for about 120 seconds and play that trace movement Picture 10 1 Picture 10 2 Practising and stop of PTZ trace Keypad 8 MENU ON Practicing ...

Страница 10: ...of buzzer When setting Alarm off buzzer and tlickering vanish 6 Maintenance and Mending If the surface of the controller unit becomes dirty turn off the power and wipe the surface with a soft dry cloth CAUTION Never use strong cleaners such as alcohol benzene or paint thinner to clean the surface of the unit They will damage the surface and could cause fire or other accidents Cleaning and inspecti...

Страница 11: ...erature 5 C 50 C Working humidity 10 75 Storage humidity 10 95 Dimension 338 L x 180 W x 45 H Weight about 1 2 Kg 2 Junction box Item Specification Power supply In output terminal DC 9V 500mA Adapter In output terminal Modular jack Control I F between camera and controller RS 485 RS 422 Working temperature 0 C 40 C Storage temperature 5 C 55 C Working humidity 10 75 Storage humidity 10 95 Dimensio...

Страница 12: ...nput Output Camera Ö Junction box Ö Sub key RS 485 Camera data RS 485 Camera data RS 422 In RS 422 In Camera control 1 GND RS 485 Camera data RS 485 Camera data RS 422 In RS 422 In Camera control 2 GND RS 485 RS 485 RS 485 RS 485 RS 422 In RS 422 In RS 422 In RS 422 In Sub keyboard GND SK RTS RX RTS GND Camera control 1 and 2 compose each separate drive circuit internally 6 Constitution of pin bet...

Страница 13: ...tting up Tour Start tour surveillance Stop tour surveillance ž ž MENU 1 MENU F F Joystick F N Start menu mode Mark of OSD Menu OSD Menu enter OSD Menu escape ž ž Function input Operation Function Main Sub 2 MENU ON OFF Set motion detect ON or OFF ž 3 MENU ON OFF Place of detection display ON OFF ž 4 MENU Joystick Z I Z O F F F N Mode of set up zone size displayed Expansion of zone size up down rig...

Отзывы: