background image

Mode

Clock, RPM, Wheel, Unit, Divider, Thermometer, fuel meter and ODO SETUP

1.  Setup operations include, 12/24 hour clock, shift warning RPM, numbers 
     of engine rotation per signal, wheel circumference, Speed input divider, 

     units, units of temperature, temperature warning, fuel meter input 

     resistance selection and odometer adjustment. These must be set up 
     step by step. The computer will be automatically revert to normal mode 
     if no button is pressed for 75 seconds at any setting screen
2.  Press both MODE & RESET buttons to go into setting mode. In setting 
     mode, each press of the RESET button increments the flashing digit by 
     1 or converts units. Press MODE button to confirm the digit setting and 
     jump to next digit or next setting screen to be set. Press MODE button 
     for 2 seconds at any setting screen to finish the setting and go to normal 

     mode.
3. It displays "12 or 24H and XX:XX " symbols as well AM/PM in case you 

     select 12H. Operates buttons as descriptions of item 2 to finish clock 
     setting and jump to shift RPM warning setting. 
4. It displays the default "RPM r06500", the digit “0” flash. Follow the item 
     2 of button operation to finish the shift RPM warning setting and jump to 
     engine specification setting.
5. It displays "RPM SPC-X.X", the default value is 1.0; there are 4 options: 
    1.0, 2.0, 3.0 and 0.5. It means the numbers of engine rotation per signal. 

    For example the value 2.0 means the engine rotate 2 turns to output a 

    signal. Follow the item 2 of button operation to finish the engine 
    specifications setting and jump to wheel circumference setting screen.
6. Press RESET button to move in loop sequence from one to another 
     value of the 4 values. Press MODE button to confirm the setting and 
     go to wheel circumference setting screen. 

7. In "cXXXX" display, "c" means "Circumference", following 4 default 

     digits; flashing digit is digit to be set. Follow the item 2 of button 
     operation to finish the wheel circumference setting and jump to signal 
     divider setting.
8. It displays "P-001" for signals to be divided. Follow item 2 of button 
     operation to finish the setting and jump to unit setting. 
9. It displays KM/H or MPH, each press of RESET button converts unit; 
     press MODE button to confirm unit setting and jump to thermometer 
     unit setting. 
10. It displays " ˚C ,˚F or oFF", each press of RESET button converts ˚C, ˚F or 
       Off, the temperature bars will disappear when you select oFF mode; 
       press MODE button to confirm temperature setting and jump to 
       temperature warning setting.
11. It displays “100r” and fuel tank symbol, follow the item 2 to select 100,

       250, 510ohm, oFF, -100, -250 or -510Ohm and jump to sensor type of 

       LAP timer setting. The fuel meter bar will disappear if you select oFF

       mode

12. It displays Ir, EF1, EF2 or EF3, for configuring the lap time recording, 
      choose “Ir” if you have an IR sensor or are manually incrementing lap 
      times with the lap button. Choose EF1/EF2/EF3 if using the 
      electromagnetic field sensor. In the case where there is one transmitter
      on the circuit,choose EF1, if there are 2 transmitters choose EF2 and EF3 
      where there are 3 transmitters. Follow the item 2 to set sensor type of 
      LAP timer and jump to odometer setting.
13. It displays “ ODO & 00000X km ”, the “ X ” is from odometer testing in 
       factory, follow item 2 to setting a desired odometer and jump to clock 
       setting or return to Normal Mode. This setting screen will disappear 
       when the odometer is over 30km (18.6Miles) or your setting is over 

       30km.

Mode

Mode

Mode 2 sec

Mode 

Mode

RESET
+
MODE    
2 Sec

RESET
+
MODE    
2 Sec

Mode

Mode

Mode

Mode

Mode

Mode

Mode

Mode

Mode

WHEEL CIRCUMFERENCE TABLE

Tire Size

Tire Size

Tire Size

23 inch
24 inch
25 inch
26 inch

19 inch
20 inch
21 inch
22 inch

15 inch
16 inch
17 inch
18 inch

1835
1915
1995
2075

1516
1596
1676
1756

1197
1277
1357
1436

1. The details below have been calculated using following formula: 

    Tire Diameter (inches) x 25.4(mm/inches) x 3.1416 

    = wheel circumference (in mm).

2. Identify the tire size of your ATV/Motorcycle when you need 

    to change different tire size and key in the corresponding 

    number shown in the following chart. 

3. These values are approximate and will differ for different brands of tyre, 

     we would always recommend that you measure the distance travelled 

     per revolution of the wheel in mm and enter this into the computer.

4. The computer calculates the wheel rotating length between 2 passes 

     of the magnet; use this table to find the settings when you are using 

     a reed sensor or an universal hall sensor with magnet to measure your 

     speed. 

5. If you are using a cable drive speed sensor then divide the number in 

    the above table by the number of turns of the cable drive for each 

    revolution of the wheel. For example if 1 wheel revolution equals 5 

    turns of speed cable then the wheel circumference has to be divided 5. 

Change display of TEMP 1 & 2: 

1. Press and hold MODE button for 2 seconds converts TEMP 1 or 2. 
2. The screen will change to TEMP 1 automatically in case engine 

     temperature is higher than the preset warning temperature. 

Shift Warning RPM Operation

1. Press MODE button to the RPM screen; pull on the throttle until the 

    desired shift warning RPM.  

2. Press RESET button to confirm and set up the shift warning RPM. 

3. Bar-graphic tachometer and warning LED will flash to warning you 

    shift gear. 

4. Press RESET button for 2 seconds at the RPM screen to re-adjust the 

    shift warning RPM

Remote Control Switch for LAP timer: 

1. The remote control switch has 2 buttons: MODE and LAP. The MODE 

     button has the same function as on the main unit. 

2. Press and hold the LAP button for 2 seconds to go into the LAP mode. 

3. LAP Record operations: 

     In LAP mode, press LAP button to start the LAP recording function, 

     each press of MODE button records a set of data LAP & AVG and 

     displays LAP timer for 3 seconds then changes display to speed 

     mode automatically, press LAP button to convert stop or start LAP 

     record function, press and hold the LAP button for 2 seconds to go 

     out LAP mode and return to normal mode. 

Lap

Mode

LAP review operations: 

1. In the LAP mode, press MODE button to review the 1st storage data, 
     it displays number of lap and lap timer. 
2. Press the RESET button to switch between lap timer or average 
     speed of the same LAP; each press of the MODE button displays 

     data for the next lap. 

3. Press and hold LAP buttons for 2 seconds to go out LAP mode and 

     return to normal mode. 

Mode

Lap

2 Sec.

Normal Mode  

LAP 

2 Sec

Lap Mode

Lap Review Mode

RESET Button    

1. Press MODE button to the desired screen then press RESET button 

     for 2 seconds to reset TRIP 2, MAX SPD/MAX TEMP 1/ MAX RPM 

     data from stored values to zero individually. 

2. The data of Trip 1, AVG & RT will all be reset at the same time when 

     one of the 3 data functions is being reset.   

3. ODO, clock and TT data cannot be reset. 

RESET    

2 Sec

Backlight Color Adjust:  

1. Press MODE button to get to the VOLT screen when not moving; 

    push and hold RESET button for 2 seconds to go into backlight 

    color setting mode. 

2. It displays “LED and -7-7-7”, the 3 numbers indicate each color of 

    Red, Green or Blue color to be adjustable, each color has 8 levels 

    0, 1, 2,..7 for setting, “0” means the color is off, “7” means the color 

    is turned on 100%. 

3. Each press of the RESET button increments the flashing digit by 1, 

    press MODE button to confirm the flashing digit setting and jump 

    to next digit to be set. Press MODE button for 2 seconds to finish 

    the setting and go to normal mode. 

RESET  

2 Sec

Mode

Mode

Mode

Red Color Setup

Green Color Setup

Blue Color Setup

Normal Mode  

LAP 

2 Sec

Lap

Lap Mode

Start Record

Mode

Mode

Mode

Lap

2 Sec.

6. You can use more magnets, but the wheel circumference setting must 

     be divided by the number of magnet you installed. 

7. The computer has a built-in software divider setting from 1 to 199 pulses 

     for different speed signal application, refer to the divider setup, one means

     one wheel revolution creates one signal. You have to input the number of 

     signal per wheel revolution to get a correct speed. We suggest to set divider 

     at 1 and adjust wheel circumference for normal ACE-S type reed sensor or 2 

     wires hall sensors, and set the P for gear sensor which has more signals for 

     one wheel revolution.

Circumferen ce 

number
(mm)

Circumferen ce 

number
(mm)

Circumferen ce 

number
(mm)

Reset

Mode

Lap

2 Sec.

DIGITAL GEAR INDICATOR INSTALL & SETUP

1.set Number of gears(Defaul=6)
2.LCD show 4~8 and Flashing
3.Press RESET key to change the 
   number of gears

1.Press MODE key to next setting mode
2.LCD show 1 and Flashing
3.Select you motorcycle to 1st Gear

1.Run the Engine at between 2000~4000 RPM
2.fix the speed & rpm about 5 seconds until the
   -flashing

1.LCD show 2 and Flashing

2.Select you motorcycle to 2st Gear

3.Run the Engine at between 2000~4000 RPM

4.fix the speed & rpm about 5 seconds until the

   -flashing

Press Mode key to return Normal Mode

Отзывы: