background image

Microphone Descriptions

1)

Cartridge module

- This is where you would sing into.

2)

Microphone body

- The main frame of the microphone.

3)

Operating indicator

 

and

 

    

Hold the switch

 

button for 1 second to turn on the  power. Light will turns green means 

microphone is now in working condition. 

    

When it lights up green

then

 

press

 

switch

 

button

 

shortly

the

 

light

 

will

 

turn

 

yellow

,

 

means

 

microphone

 

is

 

in

 

mute

 

mode

no

 

sound

 

will

 

comes

 

out

 

from

 

microphone

to

 

go

 

back

 

to

 

working

 

mode

press

 

the

 

switch

 

button

 

shortly

 

again

the

 

light

 

will

 

turn

 

green. 

    

When

 

IR

 

syncing

microphone

 

needs

 

to

 

stay

 

power

 

on

but

 

can

 

be

 

either

 

working

 

or

 

mute

 

mode

After

 

switching

 

channel

 

on

 

the

 

receiver and

 

start

 

IR

 

syncing

Then

 

put

 

the

 

button

 

part

 

of

 

the

 

microphone

 

to

 

face

 

the

 

IR

 

launcher

 

on

 

the

 

receiver

the

 

distance

 

need

 

to

 

be

 

under

 

1

 

meter

Press

 

the

 

microphone

 

switch

 

button

 

shortly

 

to

 

confirm

 

the

 

IR

 

syncing

.

 If IR sync successes, the CH in the LCD screen will stop 

flashing and you can see the RF signal bar on the LCD screen.  

5)Battery cover
6)IR

 

receiver & charging unit 

- This is the base of the microphone. The

 

bottom

 

part

 

has

 

a

 

IR

 

receiving

 

unit

 

inside

 

which

 

receive

 

the

 

IR

 

signal

 

from

 

receives

 

to

 

complete

 

the

 

IR

 

matching

 

for

 

microphone

 

and

 

receiver

4)Switch

 

button-

Microphone Operation & Channel switching:

1

)

Install

 

batteries into microphone handheld

.

2)Turn

 

on

 

microphone

 

by

 

pushing

 

the

 

switch towards, the indicator should turn green.

3)To mute the microphone, push the switch button

 

shortly

the

 

light

 

will

 

turns

 

yellow

.

4)To turn off the microphone, push the switch button

 

for

 

about

 

1

~

2

 

seconds

 

then

 

release 

it, the indicator light

 

will

 

turns

 

off

.

5)If you are not going to use the microphone for a long period of time, turn off the 
microphone and pull out the batteries to avoid deterioration and damage toward the 
components.

6)

When

 

IR

 

syncing

microphone

 

needs

 

to

 

stay

 

power

 

on

but

 

can

 

be

 

either

 

working

 

or

 

mute

 

mode

After

 

switching

 

channel

 

and start

 

IR

 

syncing on

 

the

 

receiver 

.  

Put

 

the

 

button

 

part

 

of

 

the

 

microphone

 

to

 

face

 

the

 

IR

 

launcher

 

on

 

the

 

receiver

the

 

distance

 

need

 

to

 

be

 

under

 

1

 

meter

Press

 

the

 

microphone

 

switch

 

button

 

shortly

 

to

 

confirm

 

the

 

IR

 

syncing

if

 

IR

 

syncing

 

got

 

confirmed

the

 

channel

 

information

 

on

 

the

 

LCD

 

of

 

receiver

 

will

 

stop

 

flashing and you can see the RF signal bar on the LCD screen.  

* For quick microphone channel matching process, please see the note on the top of 
receiver, or see page 7 for more  detail

.

6

12

08

XR

Содержание UHF-1208XR

Страница 1: ...ely and to its fullest potential please read this user s manual carefully before operation and keep for future reference www acesonic com The Leader in Professional Equipment UHF 1208XR DUAL DIVERSITY...

Страница 2: ...maintenance servicing instructions in the literature accompanying the appliance 1 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 o...

Страница 3: ...manufacturer 23 Wet location marking Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus 1 Read These Instruction...

Страница 4: ...08X receiver 1 l Rechargeable Battery 4 Be sure to keep original packaging in case of re shipping is needed l l Antenna 2 l User manual warranty card 1 l Microphone Battery Recharging Dock 1 3 ft male...

Страница 5: ...eiver channel 2 Scan use to start auto channel scanning process usually will need about 90 seconds to complete the process after scanning receiver will pick the best channel 3 IR to start IR sync chan...

Страница 6: ...ing unit inside which receive the IR signal from receives to complete the IR matching for microphone and receiver 4 Switch button Microphone Operation Channel switching 1 Install batteries into microp...

Страница 7: ...cess The whole auto scanning process will be finished around 90 seconds However you can stop auto scanning anytime by pressing STOP button Receiver will select the best cleanest channel from the chann...

Страница 8: ...ceiver end and wall outlet end l See page 6 and 7 for more detail l The transmitter is out of range l Microphone switch is off or mute l Microphone volume is turn down l Batteries in the microphone ar...

Страница 9: ...ions Receiver Carrier Wave Frequency Range UHF 668 692 MHz Oscillation Mode Phase locked Loop controlled Carrier Wave Stability 10PPM Switching bandwidth 24MHz Frequency Space 250KHz Sensitivity 105dB...

Страница 10: ...Information Contact Info 1 Year Manufacturer Warranty Lifetime Tech Support Design in U S A Tech Support Address 161 S 8th Avenue City of Industry CA 91746 3208 USA Website www acesonic com 626 820 0...

Отзывы: