18
Chapter 1
(This is for 145 power supply)
NOTE: Measure at line input 90 VRMS and maximum load condition
Switching Power Supply 100W
Input Frequency
Frequency Variation Range
50Hz
47Hz to 53Hz
60Hz
57Hz to 63Hz
Input Voltage
Variation Range
100 - 120 VRMS
90-132 VRMS
200 - 240 VRMS
180-264 VRMS
Input Current
Measuring Range
3A
90 -132 VRMS
1.5A
180 - 264 VRMS
Output Requirements
Regulation
Current Rating
+5V
+-5%
14A
+12V
+-5%
1.5A
-12V
+-10%
0.2A
+3.3V
+-4%
8A
+5Vaux
+-5%
2A