3-2
PH530
Confidential
No
Symptom
Procedure
4
No Light On
- Ensure all connectors are securely connected and
aren’t broken
- Check Lamp Module
- Check DC-DC
- Check Ballast
- Check Main Board
5
Mechanical Noise
- Check Color Wheel
- Check Fan Module
6
Line Bar / Line
Defect
- Check if the DMD Chip and the DMD Board are
assembled properly
- Check DMD Board
- Check DMD Chip
- Check Main Board
7
Image Flicker
- Do “Reset” of the OSD Menu
- Ensure the Signal Cable and Source work
- Clean Photo Sensor Board
- Check Lamp Module
- Check Color Wheel
- Check DMD Board
- Check Main Board
8
Color Abnormal
- Do “Reset” of the OSD Menu
- Adjust Color Wheel Index
- Check Main Board
- Check DMD Board
- Check Color Wheel
9
Poor Uniformity /
Shadow
- Ensure the Projection Screen without dirt
- Ensure the Projection Lens is clean
- Ensure the Brightness is within spec.
(Replace the Lamp if the Brightness is less
than spec.)
- Check Engine Module
0
Dead Pixel / Dust
(Out of spec.)
- Ensure the Projection Screen without dirt
- Ensure the Projection Lens is clean
- Clean DMD Chip and Engine Module
- Check DMD Chip
- Check Engine Module
Garbage Image
- Ensure the Signal Cable and Source work
- Check Main Board
- Check DMD Board
Содержание PH530 series
Страница 14: ...2 PH530 Confidential No Procedure Photo 3 1 Unscrew 2 hex screws as green circle 2 Remove Rear Cover ...
Страница 56: ...PH530 7 1 Confidential Appendix A Exploded Overview D C PH530 FOR ACER ...
Страница 59: ...PH530 7 4 Confidential ASSY TOP COVER MODULE ...
Страница 61: ...PH530 7 6 Confidential ASSY BOTTOM HOUSING MODULE ...
Страница 63: ...PH530 7 8 Confidential ASSY BOTTOM BASE MODULE ...
Страница 67: ...PH530 7 12 Confidential SUB ASSY ENGINE MODULE ...