P5271/P5290/P5390W/P5271i
Confidential
4-5
Full white
- Test signal: analog 1024 x 768@60Hz (for
P5271/P5290/P5271i);
/P5271i););
1280 x800@75H (for P5390W)
- Test Pattern: Gray 10
Inspection item
- Bright pixel check.
Criteria
- Bright pixel should be no more than 1 under
gray 10 pattern.
- Adjacent pixels are unacceptable.
- Ref. Defect specification table
3. Dark Pixel
Procedure
- Test equipment: video generator
- Test signal: analog 1024 x 768@60Hz (for
P5271/P5290/P5271i);
1280 x800@75H (for P5390W)
- Test Pattern: Full white
Inspection item
- Dark pixels check.
Criteria
- The dark pixel should be no more than 6 under
full white pattern.
- Adjacent pixels are unacceptable.
- Ref. Defect specification table
4. Bright Blemish
Procedure
- Test equipment: video generator
- Test signal: analog 1024 x 768@60Hz (for
P5271/P5290/P5271i);
1280 x800@75H (for P5390W)
- Test Pattern: Gray 15
Inspection item - Bright blemish check.
Criteria
- The bright blemish should be no more than 10
under gray 15 pattern.
- Ref. Defect specification table
5. Dark Blemish
Procedure
- Test equipment: video generator
- Test signal: analog 1024 x 768@60Hz (for
P5271/P5290/P5271i);
Gray 15
Gray 10
Содержание P5271 Series
Страница 18: ...Confidential 1 11 P5271 P5290 P5390W P5271i Remote Control Layout ...
Страница 22: ...Confidential 1 15 P5271 P5290 P5390W P5271i System Block Diagram P5271 ...
Страница 23: ...P5271 P5290 P5271i P5390W Confidential 1 16 Bottom Cover Dimension ...
Страница 107: ...P5271 P5290 P5390W P5271i Confidential 13 2 9 5 8 6 3 5 4 1 10 11 12 7 ASSY BOTTOM COVER MODULE ...
Страница 114: ...P5271 P5290 P5390W P5271i Confidential XII 3 12 13 14 15 10 11 15 7 6 8 4 5 2 1 9 ASSY ENGINE MODULE ...
Страница 119: ...P5271 P5290 P5390W P5271i Confidential XVII A K 5 7 12 9 13 8 3 6 14 14 2 4 1 11 15 16 17 18 19 10 20 ...