background image

Category

Item

Specification

Power

USB Type C Power Input

DC 5V 2A

DC-in Power Input

DC 9-24V 2A

DC-Out Power Output

DC 5V

Display

TFT LCD 320x240 16bit color display

Touch Button

5 x Capacitive Touch Button

Air Quality Light

Full color breathing light
Green:

 Good

Yellow: 

Moderate

Orange: 

Unhealthy for Sensitive Group

Red:

 Unhealthy

Purple:

 Very Unhealthy

RTC Backup Battery

CR1220 3V Coin Battery

Human-Machine

Interface

CO2

Method:

 NDIR (Non-Dispersion Infrared)

Range:

 0-10,000

ppm

Resolution:

 1

ppm

Temperature

Method:

 Semiconductor

Range:

   0-100

°C

Resolution:

 0.1

°C

Relative Humidity

Particulate Matter

Method:

 Semiconductor

Range:

   0-100

%

Resolution:

 0.1

 

Method:

 Laser Scattering

Range:

 0-1,000

μg/m

3

Sensor

 <Note 1>

Содержание MATE

Страница 1: ...Air Monitor MATE ...

Страница 2: ...hing to manual speed the timer will be set to 30 minutes by default After 30 minutes the controller will switch to automatic mode Timer In manual mode each press on the button corresponds to 1hr increment Once the time exceeds 6hr the decide would be in always on mode and the device would display 24hr Touch Button Description I ...

Страница 3: ...ed information related to the Main page Setting Button In the settings page press the button to switch and configure options Main Page Switch Button There are 5 main pages Press this button to switch main page sequentially Default Main Page Sensor Page Ventilation Equipment Page Settings About Touch Button Description II ...

Страница 4: ...1 NO3 can be used for controlling fan speed in order Only one of NO1 NO3 can be switched on at a time NO4 can be used to turn on a relay switch for further controlling a dehumidifier compressor or valve AO Analog Output GND A B A B 1 2 GND DC in DC out 1 2 3 4 AO Normal Open Slave Ain Power Master ...

Страница 5: ...Switch for touch lock RS485 120ohm MODBUS ID A0 AF USB Type C Power Connnector Screw hole for Wall Mount Plate Dip switch LORA Version ON Turn on LORA communication and turn off RS485 slave function ...

Страница 6: ...sioning ON OFF Connecting to access point OFF Slow flashing Connecting to cloud server OFF Fast flashing Connected to cloud server OFF ON Communication Error to Sensor Slow flashing Slow flashing Description of Wi Fi LED Light Wi Fi Reset Long press reset button to switch Wi Fi to provision waiting mode ...

Страница 7: ... an AMM device then click to select an equipment Follow the steps indicated on APP to complete the settings Notice Scan right QR Code to download the APP Air Monitor Pro INDOOR IAQ Air Monitor Pro INDOOR IAQ 58 AMM012 Air Quality Moderate 2021 03 09 16 34 11 Dry contact RS485 AUTO 1 AUTO 2 AUTO 1 IAQ Filter in good condition The Filter needs to be replaced OFF ANALYSIS CONTROL SETTING OVERVIEW Ven...

Страница 8: ...k Schedule On schedule setting page click on the table column corresponding to each hour to turn it on or off Notice When the schedule control is enabled AMM will switch to automatic control mode over time When the schedule is set to ON the automatic control is started When the schedule is set to OFF it turns to the off mode SETTING CONTROL Ventilator Purifier Schedule Sun Mon Tue Wed Thu Fri Sat ...

Страница 9: ...er will disappear after 5 seconds automatically Please complete the pairing process in time Bluetooth Remote Control Launch APP Click manual icon then click Scan Bluetooth air quality broadcasts Select the AMM that has strongest signal The LCD display on the corresponding AMM device will show a 4 digit number Input the 4 digit number on APP to complete paring process and then you can perform remot...

Страница 10: ...ilter needs to be replaced Notice Please contact business window for LORA relative functions LORA Configuration Please login the cloud account into LoRa Master device for setting the connection Once the setting is completed you can use the APP to access the AMM Air Monitor Pro IAQ Air Monitor Pro 成功連線 後方WiFi燈號為綠燈 裝置名稱 AMM010 ...

Страница 11: ...tween the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rule...

Страница 12: ...ght Green Good Yellow Moderate Orange Unhealthy for Sensitive Group Red Unhealthy Purple Very Unhealthy RTC Backup Battery CR1220 3V Coin Battery Human Machine Interface CO2 Method NDIR Non Dispersion Infrared Range 0 10 000ppm Resolution 1ppm Temperature Method Semiconductor Range 0 100 C Resolution 0 1 C Relative Humidity Particulate Matter Method Semiconductor Range 0 100 Resolution 0 1 Method ...

Страница 13: ...z Wired Communication MODBUS RTU protocol over RS 485 9600bps 8n1 LORA 920MHz Peer to Peer Communication SD Card Slot Micro SDCARD 32GB FAT32 File System RS 485 MODBUS RTU protocol over RS 485 Master 9600bps 8n1 Analog 0 10V output control Digital 4 port Normal Open Control Point Communication Note 2 Storage Control Category Item Specification Note 1 The sensor is equipped according to the product...

Страница 14: ...screws 1 2 Lock the barb rack to the back cover with salad head screws 1 Lock the wall mount plate on the double box with self tapping screws Self tapping screws are placed in the gecko screw group 2 Align the barb hanger with the rectangular hole on the wall mount Past down fixed and lock with hexagon socket screws 3 3 ...

Страница 15: ...internal burns in just 2 hours and can lead to death Keep new and used batteries away from children If the battery compartment does not close securely stop using the product and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention ...

Страница 16: ... 2021 Acer Inc All Rights Reserved ...

Отзывы: