H a n n St a r D i s p l a y C o r p .
Document Title
HSD190MEN3-A
Specification for Innolux
Page No.
20 / 26
Document No.
DC130-002772
Revision
1.0
The information contained in this document is the exclusive property of HannStar Display Corporation. It shall not
be disclosed, distributed or reproduced in whole or in part without written permission of HannStar Display
Corporation.
6.4 Power On / Off Sequence
:
Item Min. Typ. Max.
Unit
Remark
TP1 0.5 -- 10
msec
TP2 0 -- 50
msec
TP3 0 -- 50
msec
TP4 500 --
--
msec
TP5 200 --
--
msec
TP6 200 --
--
msec
Note
:
(1) The supply voltage of the external system for the module input should be the
same as the definition of V
DD
.
(2) Apply the lamp volatge within the LCD operation range. When the back-light
turns on before the LCD operation or the LCD truns off before the back-light turns
off, the display may momentarily become white.
(3) In case of VDD = off level, please keep the level of input signal on the low or
keep a high impedance.
(4) TP4 should be measured after the module has been fully discharged between
power off and on period.
(5) Interface signal shall not be kept at high impedance when the power is on.
Power Supply
Signal
Backlight
(Recommended
)
0V
0V
Power On
Power Off
0.9V
DD
0.1V
DD
0.9V
DD
0.1V
DD
0.1V
DD
0.6V 0.6V
50%
50%
TP1
TP2
TP3
TP4
TP5
TP6
Содержание B193
Страница 1: ... 0 Service Manual LCD Monitor Acer B V193 ...
Страница 16: ...15 Note Please see the configure as below Figure 6 Programmi ng speed Configure Inform ...
Страница 18: ...17 02 Flat Panel Specification ...
Страница 43: ......
Страница 44: ......
Страница 45: ...22 04 Troubleshooting ...
Страница 46: ...23 ...
Страница 47: ...24 ...
Страница 50: ...27 06 Schematics and Layouts 6 1 Inverter PWM circuit ...
Страница 51: ...28 6 2 Switching Mode Power Supply circuit ...