83
Chapter 4
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
System Check” on page 68):
1.
Power-off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
T
Non-Acer devices
T
Printer, mouse, and other external devices
T
Battery pack
T
Hard disk drive
T
DIMM
T
CD-ROM/Diskette drive Module
T
PC Cards
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
T
System board
T
LCD assembly
Содержание Aspire 3000 Series
Страница 6: ...6...
Страница 9: ...III Table of Contents...
Страница 40: ...Chapter 1 31...
Страница 53: ...Chapter 2 44...
Страница 54: ...45 Chapter 2...
Страница 61: ...Chapter 3 52...
Страница 66: ...57 Chapter 3...
Страница 73: ...Chapter 3 64...
Страница 74: ...65 Chapter 3...
Страница 96: ...87 Chapter 5...
Страница 112: ...Appendix A 103...
Страница 118: ...109 Appendix B...
Страница 120: ...111 Appendix C...
Страница 123: ...Index 104...