41
9.4
Rise-Time : 5ns
±±±±
30%
9.5
Impulse Duration: 50 nS
±±±±
30%
9.6
Relation to Power Supply: Asynchronous
9.7
Burst Duration: 15 ms
±±±±
20%
9.8
Burst Period: 300 ms
±±±±
20%
9.9
Climatic Conditions:
- Ambient Temperature: 15
°
C to 35
°
C
- Relative Humidity: 45% to 75%
- Atmospheric Pressure: 86 kPa to 106 kPa
9.10
Test Procedure:
The monitor Display set high-resolution mode, AC input use AC 240V.
Note :
9.10.1
IEC 61000-4-4 defines that power supply, I/O line, and control line all shall be performed
the transient test, but the I/O line and control line is applied with only half of peak voltage
(1 KV).
9.10.2
For the comparison of wave-shape generated by different generator, so the test must uses
a scope with at least 400 MHz bandwidth, and coupled to 50
Ω
to monitor the rise-time,
impulse, duration, and repetition rate of the impulses within one burst.