6
2. ADJUSTMENT CONDITIONS
A. Measuring Apparatuses Used
Necessary measuring equipment that for the adjustment of LA-1221JMW’s MAIN PWB are
following items.
Adjusted Video Generator.
Oscilloscope (more than 4 channels required)
DC voltmeter
B. Input Signal
Input signal by using video signal generator with VGA Card port for this adjustment.
C. Indication
Input signal by using video signal generator with VGA Card port for this adjustment.
3. ADJUSTMENT of Power Supply
Input
voltage
AC
100
~
240Vac
Rated input voltage
AC 90 ~ 264Vac
Frequency
50
/
60
Hz
Rated frequency
47 ~ 63 Hz
DC
output
Out voltage
+12V
+5V
Maximum output current
+1.5A
+1.5A
Minimum output current
0A
+0.1A
Range of voltage Regulation
+15%~-5%
±
5%
Содержание AL511
Страница 11: ...11 F 2 ...
Страница 20: ...20 10 TROUBLESHOOTING A Main Procedure ...
Страница 21: ...21 A 1 Power Circuit Troubleshooting ...
Страница 22: ...22 A 2 Backlights Troubleshooting ...
Страница 23: ...23 A 3 Performance Troubleshooting ...
Страница 24: ...24 A 4 Function Troubleshooting ...